# Problem codes: Expressions, stocks and flows

Expressions and variables, tables and time series, levels, flows, conversions, conveyors, delays, subscripts and units. The list is generated from the codes' own table; the meaning is the table's sentence for the code.

| Code | Severity | Meaning | About |
|---|---|---|---|
| <span id="e_assign_key"></span>`E_ASSIGN_KEY` | error | An ASSIGN entry has a key other than `target` and `expr` (it would be ignored). On screen: "Block {block}: assignment {index} has an unknown key" | [ASSIGN](../blocks/assign.md) |
| <span id="e_assign_target"></span>`E_ASSIGN_TARGET` | error | An ASSIGN target is not a writable `entity.<attr>` or variable name. On screen: "Block {block}: assignment target {target} is not valid" | [ASSIGN](../blocks/assign.md) |
| <span id="e_aux_cycle"></span>`E_AUX_CYCLE` | error | Auxiliaries read each other in a cycle. On screen: "Auxiliaries read each other in a cycle: {cycle}" | [`auxiliaries`](../model-file/auxiliaries.md) |
| <span id="e_aux_name"></span>`E_AUX_NAME` | error | An auxiliary has an empty or duplicate name. On screen: "An auxiliary has no name" / "Auxiliary {name} is defined twice" | [`auxiliaries`](../model-file/auxiliaries.md) |
| <span id="e_aux_unknown"></span>`E_AUX_UNKNOWN` | error | A literal AUX("name") call names no declared auxiliary. On screen: "{block}: no auxiliary named {name}" | [`auxiliaries`](../model-file/auxiliaries.md) |
| <span id="e_buffer_level"></span>`E_BUFFER_LEVEL` | error | A BUFFER's "level" names a level the model does not declare. On screen: "Block {block}: level {level} does not exist" | [BUFFER](../blocks/buffer.md), [`levels`](../model-file/levels.md) |
| <span id="e_charge"></span>`E_CHARGE` | error | A CHARGE block's sharing rule is neither "equal" nor "first_come", its efficiency is not in (0, 1], or it keeps a full entity (leave_when_full off) with no time limit to leave by. On screen: "Block {block}: unknown sharing rule {sharing}" / "Block {block}: staying when full needs a time limit" / "Block {block}: efficiency must be above 0, at most 1" | [CHARGE](../blocks/charge.md) |
| <span id="e_conversion_curve"></span>`E_CONVERSION_CURVE` | error | A substrate's yield or release curve is malformed: a bad "yield", no curve and no positive "half_life", non-increasing knots, or a curve that does not end at 1.0. On screen: "{where}: yield must be a number, 0 or more" / "{where}: needs a curve or a positive half life" / "{where}: steps must be at least 1" / "{where}: the curve must be a list of pairs" / "{where}: every curve knot needs an age and a fraction" / "{where}: curve ages must rise, fractions must not fall" / "{where}: the last curve knot must be 1, not {last}" | [`conversions`](../model-file/conversions.md) |
| <span id="e_conversion_interval"></span>`E_CONVERSION_INTERVAL` | error | A conversion's "cohort_interval" is not a positive number. On screen: "Conversion {name}: cohort interval must be above 0" | [`conversions`](../model-file/conversions.md) |
| <span id="e_conversion_name"></span>`E_CONVERSION_NAME` | error | A conversion has an empty or duplicate name, or is not an object. On screen: "A conversion entry is not an object" / "A conversion has no name" / "Conversion {name} is defined twice" | [`conversions`](../model-file/conversions.md) |
| <span id="e_conversion_substrate"></span>`E_CONVERSION_SUBSTRATE` | error | A conversion declares no substrate, or one with an empty or duplicate name. On screen: "Conversion {name} needs at least one substrate" / "Conversion {name}: a substrate has no name" / "Conversion {name}: substrate {substrate} is listed twice" | [`conversions`](../model-file/conversions.md) |
| <span id="e_conversion_unknown"></span>`E_CONVERSION_UNKNOWN` | error | A CONV("name") call names a conversion the model does not declare. On screen: "{block}: no conversion named {name}" | [`conversions`](../model-file/conversions.md) |
| <span id="e_conveyor_divert"></span>`E_CONVEYOR_DIVERT` | error | A CONVEYOR divert is not {at, condition, time?, when_full?}, its `at` is off the belt or on another point, its condition is empty, its time is not a number &gt;= 0 or an expression, its when_full is not wait/pass, the belt has fewer links than 1 + diverts, a "pass" divert's link does not go straight to a CONVEYOR, BUFFER or queue_capacity station, or an intercept divert has a push time or when_full, a bad on_late, or a link that is not the robot picking from it, a divert's side is not left or right, or a link out of the belt names an exit that is not out or d&lt;k&gt;, or a routing rule is not usable, is not on the first divert of its rule_group along the belt, has an exit count other than its group's diverts, or sits beside a condition, a robot pick or when_full "pass", or a rule exit names a target piece that is not a CONVEYOR its loads reach; or a CONVEYOR_TRANSFER's links do not match its exits one to one (a port that is not one of its exits, or named twice), or its routing rule is not usable. On screen: "Belt {block}: divert {index} has the wrong settings" / "Belt {block}: divert {index} is not on the belt" / "Belt {block}: divert {index} shares a point on the belt" / "Belt {block}: divert {index} needs a condition" / "Belt {block}: divert {index} needs a time of 0 or more" / "Belt {block}: divert {index} must wait or pass when full" / "Belt {block}: robot divert {index} takes no push time or full rule" / "Belt {block}: exit {port} is not out or a divert" / "Belt {block}: exit {port} has two links" / "Transfer {block}: exit {port} is not one of its exits" / "Transfer {block}: exit {port} has two links" / "Transfer {block}: {exits} exits need as many links out, has {links}" / "Transfer {block}: its routing rule does not work" / "Belt {block}: divert {index} side must be left or right" / "Belt {block}: divert {index} has no valid late rule" / "Belt {block}: divert {index} must link straight to its robot" / "Belt {block}: {diverts} diverts need {needed} links out, has {links}" / "Belt {block}: divert {index} leads to a block with no places" / "Belt {block}: the routing rule at divert {index} does not work" / "Belt {block}: divert {index} is in a badly set rule group" / "Belt {block}: routed divert {index} takes no condition, robot or pass" / "Block {block}: exit {exit} names {target}, no conveyor on its way" | [BUFFER](../blocks/buffer.md), [CONVEYOR](../blocks/conveyor.md), [CONVEYOR_TRANSFER](../blocks/conveyor-transfer.md) |
| <span id="e_conveyor_eye"></span>`E_CONVEYOR_EYE` | error | A CONVEYOR photo-eye is not on the belt, shares its place with another point, has an edge other than front or back, or the belt's part_length is longer than its spacing. On screen: "Belt {block}: eye {index} has the wrong settings" / "Belt {block}: eye {index} is not on the belt" / "Belt {block}: eye {index} shares a point on the belt" / "Belt {block}: eye {index} sees a back edge past the end" / "Belt {block}: eye {index} edge must be front or back" / "Belt {block}: eye {index} assignment {row} needs a target and an expression" / "Belt {block}: eye {index} signal must be a name" / "Belt {block}: its part length is longer than its spacing" / "Belt {block}: an item does not fit its belt cell or eye" | [CONVEYOR](../blocks/conveyor.md) |
| <span id="e_conveyor_grid"></span>`E_CONVEYOR_GRID` | error | A conveyor stock needs simulation.sd (it moves one slat per DT). On screen: "Conveyor {name}: needs the system-dynamics time step" | [CONVEYOR](../blocks/conveyor.md) |
| <span id="e_conveyor_leak"></span>`E_CONVEYOR_LEAK` | error | A leak on a flow that is not a conveyor's outflow, with no fraction, or with a zone outside 0 &lt;= start &lt; end &lt;= 1. On screen: "Flow {name}: a leak must start at a conveyor" / "Flow {name}: a leak needs a fraction" / "Flow {name}: leak zone must run from 0 up to 1" | [CONVEYOR](../blocks/conveyor.md) |
| <span id="e_conveyor_merge"></span>`E_CONVEYOR_MERGE` | error | A CONVEYOR merge is not {at, from, priority?}, its `at` is off the belt or on another point, its `from` is not a block linking to the belt or is named twice, its priority is not belt/merge, or the belt is not accumulating. On screen: "Belt {block}: merges need an accumulating belt" / "Belt {block}: merge {index} has the wrong settings" / "Belt {block}: merge {index} is not on the belt" / "Belt {block}: merge {index} shares a point on the belt" / "Belt {block}: merge {index} needs its own source block" / "Belt {block}: merge {index} priority must be belt or merge" / "Belt {block}: merge {index} names {source}, which is not linked to it" | [CONVEYOR](../blocks/conveyor.md) |
| <span id="e_conveyor_method"></span>`E_CONVEYOR_METHOD` | error | A conveyor stock under method rk4; conveyors need euler. On screen: "Conveyor {name}: needs the Euler method" | [CONVEYOR](../blocks/conveyor.md) |
| <span id="e_conveyor_outflow"></span>`E_CONVEYOR_OUTFLOW` | error | A conveyor has no or several primary (non-leak) outflows, or its primary outflow has a rate. On screen: "Conveyor {name}: needs exactly one main outflow, has {n}" / "Flow {name}: a conveyor's main outflow takes no rate" | [CONVEYOR](../blocks/conveyor.md) |
| <span id="e_conveyor_param"></span>`E_CONVEYOR_PARAM` | error | A CONVEYOR's type is not belt, roller, chain, pallet or mdr, or its length, speed or spacing is not a number &gt; 0, or its gap or cell is negative, or its endpoints name unknown nodes, or its zones are not {count &gt;= 1, release_delay &gt;= 0} on an accumulating belt with no stop, merge or routing rule that can hold a part; or a CONVEYOR_TRANSFER's mechanism is not popup, turntable or lift, an exit is not {port, angle} or shares or holds a ':' in its port, a time, length or speed is negative (a turn_rate or lift_speed not &gt; 0), or transfer_speed is 0 where a move needs it and no one CONVEYOR speed feeds the module; or a stop, divert, merge or eye of a belt with a path lies at or past the path's end, or a divert's angle is not a number above 0 and below 180. On screen: "Block {block}: {field} must be a number above 0" / "Transfer {block}: {field} must be 0 or more" / "Transfer {block}: mechanism {mechanism} is not popup, turntable or lift" / "Transfer {block}: exit {index} needs a port name and an angle" / "Transfer {block}: two exits share the port {port}" / "Transfer {block}: exit {index} port {port} has a colon" / "Transfer {block}: set its transfer speed, no single feeding conveyor gives it" / "Belt {block}: {what} is past the end of its path" / "Belt {block}: divert {index} angle must be between 0 and 180 degrees" / "Belt {block}: length must be 0 or more" / "Belt {block}: {field} must be 0 or more" / "Belt {block}: unknown network node {node}" / "Belt {block}: unknown conveyor type {type}" / "Belt {block}: no length, and no start and end nodes" / "Belt {block}: unknown resource {resource}" / "Belt {block}: its zones have the wrong settings" / "Belt {block}: zones need an accumulating belt" / "Belt {block}: zones with stops or merges are not supported yet" / "Belt {block}: zones with a holding routing rule are not supported yet" | [CONVEYOR](../blocks/conveyor.md), [CONVEYOR_TRANSFER](../blocks/conveyor-transfer.md) |
| <span id="e_conveyor_path"></span>`E_CONVEYOR_PATH` | error | A CONVEYOR's path has a piece that is not a straight or an arc, or it has a length or end nodes beside it. On screen: "Belt {block}: a piece of its path is wrong" / "Belt {block}: its path sets the length, so give no length" | [CONVEYOR](../blocks/conveyor.md) |
| <span id="e_conveyor_release"></span>`E_CONVEYOR_RELEASE` | error | A CONVEYOR's release is not one of metering {gap or interval}, singulation {gap} or slug {count, timeout, time_unit?} with numbers &gt;= 0, or the belt is not accumulating or has zones. On screen: "Belt {block}: its release rule has the wrong settings" / "Belt {block}: a release rule needs an accumulating belt" / "Belt {block}: a release rule cannot share a belt with zones" | [CONVEYOR](../blocks/conveyor.md), [RELEASE](../blocks/release.md) |
| <span id="e_conveyor_reverse"></span>`E_CONVEYOR_REVERSE` | error | A reversible CONVEYOR has stops, diverts, robot picks, merges, photo-eyes, zones or a release rule, which only work one way, or its reverse_to is missing or names no exit of the belt, or a later piece of a reversible chain names one, or the chain is a ring. On screen: "Belt {block}: a reversible belt cannot have {what}" / "Belt {block}: a reversible belt needs an exit at its start" / "Belt {block}: its start exit {target} is not linked to it" / "Belt {block}: its start exit {target} is a belt feeding it" / "Belt {block}: reversible must be true or false" / "Belt {block}: its chain start {first} names the start exit" / "Belt {block}: reversible belts in a ring have no chain start" | [CONVEYOR](../blocks/conveyor.md) |
| <span id="e_conveyor_spec"></span>`E_CONVEYOR_SPEC` | error | A conveyor has no transit_time or an unknown leak_kind. On screen: "Conveyor {name}: transit time is missing" / "Conveyor {name}: unknown leak kind {kind}" | [CONVEYOR](../blocks/conveyor.md) |
| <span id="e_conveyor_stop"></span>`E_CONVEYOR_STOP` | error | A CONVEYOR stop is not {at, time, resource?}, its `at` is not between 0 and the belt's length, its time is not a number &gt;= 0 or an expression, or its resource is not declared. On screen: "Block {block}: stop {index} has the wrong settings" / "Block {block}: stop {index} is not on the belt" / "Block {block}: stop {index} needs a time of 0 or more" / "Block {block}: stop {index} names unknown resource {resource}" | [CONVEYOR](../blocks/conveyor.md) |
| <span id="e_conveyor_write"></span>`E_CONVEYOR_WRITE` | error | Something would write a conveyor stock directly (a TRANSFER block or agent transfer action, a BUFFER's mirror level, initial_state.levels, or a subscripted conveyor), bypassing its slat model. On screen: "Agent type {agent}: {where}: cannot transfer into or out of conveyor {level}" / "Block {block}: a buffer cannot mirror into conveyor {level}" / "Block {block}: a transfer cannot use conveyor {level}" / "Level {name} is a conveyor; its start cannot be set" / "Conveyor {name}: cannot be subscripted" | [BUFFER](../blocks/buffer.md), [CONVEYOR](../blocks/conveyor.md), [TRANSFER](../blocks/transfer.md) |
| <span id="e_dashboard_series"></span>`E_DASHBOARD_SERIES` | error | A dashboard widget's series do not fit its kind: kpi/gauge take "expr" (not "series"), line takes 1-4 series and bar 1-8, with unique non-empty labels. On screen: "Widget {name}: a {kind} widget takes an expression, not series" / "Widget {name}: a {kind} widget takes series, not an expression" / "Widget {name}: a {kind} widget takes 1-{limit} series, got {got}" / "Widget {name}: series {number} has no label" / "Widget {name}: series label {label} is used twice" | [`dashboard`](../model-file/dashboard.md), [`timeseries_inputs`](../model-file/timeseries_inputs.md) |
| <span id="e_delay_name"></span>`E_DELAY_NAME` | error | A delay has an empty or duplicate name. On screen: "A delay has no name" / "Delay {name} is defined twice" / "Delay {name} shares hidden stage names with another delay" | [DELAY](../blocks/delay.md), [`delays`](../model-file/delays.md) |
| <span id="e_delay_spec"></span>`E_DELAY_SPEC` | error | A delay's kind is unknown, its input or delay_time is missing, or its delay_time is a number &lt;= 0. On screen: "Delay {name}: unknown kind {kind}" / "Delay {name}: {field} is missing" / "Delay {name}: delay time must be above 0" | [DELAY](../blocks/delay.md), [`delays`](../model-file/delays.md) |
| <span id="e_delay_unknown"></span>`E_DELAY_UNKNOWN` | error | A literal DELAY("name") call names no declared delay. On screen: "{block}: no delay named {name}" | [DELAY](../blocks/delay.md), [`delays`](../model-file/delays.md) |
| <span id="e_duplicate_reality_check"></span>`E_DUPLICATE_REALITY_CHECK` | error | Two reality checks share a name. On screen: "Reality check {name} is defined twice" | [DUPLICATE](../blocks/duplicate.md), [`reality_checks`](../model-file/reality_checks.md) |
| <span id="e_duplicate_variable"></span>`E_DUPLICATE_VARIABLE` | error | Two variables share a name. On screen: "Variable {name} is defined twice" | [DUPLICATE](../blocks/duplicate.md), [`variables`](../model-file/variables.md) |
| <span id="e_energy_price"></span>`E_ENERGY_PRICE` | error | "simulation.energy_price" is neither a number nor a valid expression. On screen: "The energy price expression is not valid" / "The energy price must be a number or an expression" | -- |
| <span id="e_expression"></span>`E_EXPRESSION` | error | An expression does not compile against the safe grammar. On screen: "Reality check {name}: the constraint is empty" / "{block}: {text} is not a valid expression" / "{block}: {text} fails on every draw" / "{block}: {text} uses self outside an agent type" / "Resource {name}: the ranking expression is not valid" | -- |
| <span id="e_fixed_cost_amount"></span>`E_FIXED_COST_AMOUNT` | error | A fixed cost's "amount" is neither a number nor a valid expression. On screen: "Fixed cost {name}: the amount expression is not valid" / "Fixed cost {name}: amount must be a number or expression" | [`fixed_costs`](../model-file/fixed_costs.md) |
| <span id="e_fixed_cost_name"></span>`E_FIXED_COST_NAME` | error | A fixed cost has an empty or duplicate name, or is not an object. On screen: "A fixed cost entry is not an object" / "A fixed cost has no name" / "Fixed cost {name} is defined twice" | [`fixed_costs`](../model-file/fixed_costs.md) |
| <span id="e_flow_biflow"></span>`E_FLOW_BIFLOW` | error | A flow's "biflow" is not a boolean, or a bi-directional flow joins a level with a bound (min, capacity or power limit). On screen: "Flow {name}: two-way must be true or false" / "Flow {name}: a two-way flow needs levels without limits" | [`flows`](../model-file/flows.md) |
| <span id="e_flow_component"></span>`E_FLOW_COMPONENT` | error | A flow's "components" is not an object of component -&gt; share. On screen: "Flow {name}: components must give each name a share" | [`flows`](../model-file/flows.md) |
| <span id="e_flow_efficiency"></span>`E_FLOW_EFFICIENCY` | error | A flow's efficiency is outside (0, 1]. On screen: "Flow {name}: efficiency must be above 0 and at most 1" | [`flows`](../model-file/flows.md) |
| <span id="e_flow_level"></span>`E_FLOW_LEVEL` | error | A flow's "from" or "to" names no declared level. On screen: "Flow {name}: {side} names no level: {end}" | [`flows`](../model-file/flows.md), [`levels`](../model-file/levels.md) |
| <span id="e_flow_min_rate"></span>`E_FLOW_MIN_RATE` | error | A flow's "min_rate" is not a number &gt;= 0. On screen: "Flow {name}: minimum rate must be 0 or more" | [`flows`](../model-file/flows.md) |
| <span id="e_flow_name"></span>`E_FLOW_NAME` | error | A flow has an empty or duplicate name. On screen: "A flow has no name" / "Flow {name} is defined twice" | [`flows`](../model-file/flows.md) |
| <span id="e_flow_peak_price"></span>`E_FLOW_PEAK_PRICE` | error | A flow's "peak_price" is not a number (a demand charge is a tariff per unit of Peak Rate, billed once at the end of the run). On screen: "Flow {name}: peak price must be a number" | [`flows`](../model-file/flows.md) |
| <span id="e_flow_tag"></span>`E_FLOW_TAG` | error | A flow's bus "tag" is not a string, or its "priority" is not a number (flows sharing a tag are summed by FLOWSUM, so one tag must not mix time units). On screen: "Flow {name}: tag must be text" / "Flow {name}: priority must be a number" / "Flows tagged {tag} use different time units" | [`flows`](../model-file/flows.md) |
| <span id="e_flow_threshold"></span>`E_FLOW_THRESHOLD` | error | A flow rate threshold has no numeric value, an unknown direction, or a non-numeric "cost". On screen: "Flow {name}: a threshold is not valid" | [`flows`](../model-file/flows.md) |
| <span id="e_flow_unknown"></span>`E_FLOW_UNKNOWN` | error | A FLOW("name") call names a flow the model does not declare. On screen: "{block}: no flow named {name}" | [`flows`](../model-file/flows.md) |
| <span id="e_level_bounds"></span>`E_LEVEL_BOUNDS` | error | A level's capacity/min/initial or a power limit is not a number, or the three bounds are inconsistent. On screen: "Level {name} must start at a number" / "Level {name}: a limit is not a number" / "Level {name}: capacity is below the minimum" / "Level {name}: start value is outside its limits" | [`levels`](../model-file/levels.md) |
| <span id="e_level_component"></span>`E_LEVEL_COMPONENT` | error | A level's component has no name, is declared twice, has an initial_fraction outside [0, 1], or the level's "blend_tolerance" is not positive. On screen: "Level {name}: a component has no name" / "Level {name}: component {label} is defined twice" / "Level {name}: component {label} start share must be 0 to 1" / "Level {name}: blend tolerance must be above 0" | [`levels`](../model-file/levels.md) |
| <span id="e_level_name"></span>`E_LEVEL_NAME` | error | A level has an empty or duplicate name. On screen: "A level has no name" / "Level {name} is defined twice" | [`levels`](../model-file/levels.md) |
| <span id="e_level_threshold"></span>`E_LEVEL_THRESHOLD` | error | A level threshold has no numeric value, or an unknown direction. On screen: "Level {name}: a threshold is not valid" | [`levels`](../model-file/levels.md) |
| <span id="e_level_unknown"></span>`E_LEVEL_UNKNOWN` | error | A LEVEL("name") call, a TRANSFER block or an agent's transfer action names a level the model does not declare. On screen: "Agent type {agent}: {where}: unknown level {level}" / "Block {block}: unknown level {level}" / "Initial state: unknown level {name}" / "{block}: no level named {name}" | [TRANSFER](../blocks/transfer.md), [`levels`](../model-file/levels.md) |
| <span id="e_log_level"></span>`E_LOG_LEVEL` | error | simulation.log_level names no run log level or profile. On screen: "Log level {level} is not a level or profile" | [`levels`](../model-file/levels.md) |
| <span id="e_loop_grid"></span>`E_LOOP_GRID` | error | Loop dominance needs the SD step grid (simulation.sd) and the model has none. | -- |
| <span id="e_power_unknown"></span>`E_POWER_UNKNOWN` | error | A POWER("name") call names no declared resource, fleet or charger. On screen: "{block}: no resource, fleet or charger named {name}" | -- |
| <span id="e_reality_check_input"></span>`E_REALITY_CHECK_INPUT` | error | A reality check's "inputs" is not an object of override path: value, or one of its paths is empty. On screen: "Reality check {name}: each input needs a path and a value" | [`reality_checks`](../model-file/reality_checks.md) |
| <span id="e_reality_check_name"></span>`E_REALITY_CHECK_NAME` | error | A reality check has an empty name. On screen: "A reality check has no name" | [`reality_checks`](../model-file/reality_checks.md) |
| <span id="e_reality_check_when"></span>`E_REALITY_CHECK_WHEN` | error | A reality check's "when" is outside the grammar ("always", "final", a window, or "eventually" with or without one), or its window ends before it starts. On screen: "Reality check {name}: its time window is not valid" | [`reality_checks`](../model-file/reality_checks.md) |
| <span id="e_sd_delay_order"></span>`E_SD_DELAY_ORDER` | error | A material/information delay's order (DELAYN's n) is not a literal integer &gt;= 1. On screen: "Delay {name}: order must be a whole number, 1 or more" | [DELAY](../blocks/delay.md), [`delays`](../model-file/delays.md), [`orders`](../model-file/orders.md), [`simulation`](../model-file/simulation.md) |
| <span id="e_sd_function_context"></span>`E_SD_FUNCTION_CONTEXT` | error | An inline SMOOTH/DELAY call sits where no delay can be generated (a block, a price); only a flow rate, an auxiliary or a delay input may hold one. On screen: "{block}: {name}() cannot be used here" | [DELAY](../blocks/delay.md), [`simulation`](../model-file/simulation.md) |
| <span id="e_sd_requires_dt"></span>`E_SD_REQUIRES_DT` | error | A material or information delay (SMOOTH, DELAY1/3/N) needs simulation.sd; a pipeline (DELAYP) does not. On screen: "Delay {name}: needs the system-dynamics time step" | [`simulation`](../model-file/simulation.md) |
| <span id="e_sd_rk4_random"></span>`E_SD_RK4_RANDOM` | error | A dynamic flow rate draws random numbers under RK4, which evaluates it four times per step. On screen: "Flow {name}: Runge-Kutta cannot draw random numbers" | [`simulation`](../model-file/simulation.md) |
| <span id="e_sd_settings"></span>`E_SD_SETTINGS` | error | simulation.sd is not an object, its "dt" is not a number &gt; 0, or its method or time_unit is unknown. On screen: "The system-dynamics settings must be an object" / "The time step must be a number above 0" / "Unknown system-dynamics method {method}" / "Unknown system-dynamics time unit {unit}" / "Unknown system-dynamics settings: {unknown}" | [`simulation`](../model-file/simulation.md) |
| <span id="e_series_mode"></span>`E_SERIES_MODE` | error | A time series' interpolation or beyond-the-end mode is unknown. On screen: "Time series {name}: unknown {key} {value}" / "A time series period is not valid" | [`timeseries_inputs`](../model-file/timeseries_inputs.md) |
| <span id="e_series_name"></span>`E_SERIES_NAME` | error | A time series has an empty or duplicate name. On screen: "A time series has no name" / "Time series {name} is defined twice" | [`timeseries_inputs`](../model-file/timeseries_inputs.md) |
| <span id="e_series_no_calendar"></span>`E_SERIES_NO_CALENDAR` | error | A time series uses real timestamps but the model has no calendar. On screen: "Time series {name}: dates need a model calendar" | [`simulation`](../model-file/simulation.md), [`timeseries_inputs`](../model-file/timeseries_inputs.md) |
| <span id="e_series_shape"></span>`E_SERIES_SHAPE` | error | A time series' values/times/step do not describe a series. On screen: "Time series {name}: timestamps must be a list of dates" / "Time series {name}: use times or timestamps, not both" / "Time series {name}: a dated start needs a step" / "Time series {name}: timestamps and values differ in number" / "Time series {name}: values must be a non-empty list" / "Time series {name}: {value} is not a number" / "Time series {name}: give either times or a step" / "Time series {name}: times and step cannot both be set" / "Time series {name}: times must be a list of numbers" / "Time series {name}: times and values differ in number" / "Time series {name}: step must be a number" / "Time series {name}: period must be a number" | [`timeseries_inputs`](../model-file/timeseries_inputs.md) |
| <span id="e_series_unknown"></span>`E_SERIES_UNKNOWN` | error | A TS("name") call names a time series the model does not declare. On screen: "{block}: no time series named {name}" | [`timeseries_inputs`](../model-file/timeseries_inputs.md) |
| <span id="e_subscript_aggregate"></span>`E_SUBSCRIPT_AGGREGATE` | error | A one-argument SUM(x)/MEAN(x) has no "[*]" to unroll over, or sits outside a level, flow, auxiliary or delay. On screen: "{block}: {name}() needs a [*] over a subscripted record" | [`subscripts`](../model-file/subscripts.md) |
| <span id="e_subscript_dim"></span>`E_SUBSCRIPT_DIM` | error | A "[dim]" index names a dimension its record does not have, a "[*]" sits outside SUM/MEAN, "dims" repeats one, or a flow joins a subscripted level without its dims. On screen: "{who}: a dimension is listed twice" / "{who}: {loose} sits outside SUM or MEAN" / "{who}: {loose} is not a dimension of this record" / "{who}: a flow end is subscripted but the flow is not" | [`subscripts`](../model-file/subscripts.md) |
| <span id="e_subscript_element"></span>`E_SUBSCRIPT_ELEMENT` | error | A record's per-element "elements" overrides are not an object, or name an element combination its "dims" do not have. On screen: "{who}: its element overrides match nothing" | [`subscripts`](../model-file/subscripts.md) |
| <span id="e_subscript_map"></span>`E_SUBSCRIPT_MAP` | error | A subscript's "map_to" names no other declared subscript, or its "elements" are not one target element per element (without them the two sizes must match). On screen: "Subscript {name}: cannot map to another subscript" | [`subscripts`](../model-file/subscripts.md) |
| <span id="e_subscript_name"></span>`E_SUBSCRIPT_NAME` | error | A subscript's name is not an identifier or is a duplicate, or its elements are empty, repeated, or hold [ ] , * or a subscript name. On screen: "A subscript name must be an identifier" / "Subscript {name} is defined twice" / "Subscript {name}: elements must be a non-empty list" / "Subscript {name}: elements must be unique plain text" / "{text} is both a subscript and an element" | [`subscripts`](../model-file/subscripts.md) |
| <span id="e_subscript_range"></span>`E_SUBSCRIPT_RANGE` | error | A subscript's "parent" is not another declared subscript holding all of its elements. On screen: "Subscript {name}: parent must hold all its elements" | [`subscripts`](../model-file/subscripts.md) |
| <span id="e_subscript_size"></span>`E_SUBSCRIPT_SIZE` | error | A subscripted record's element count (the product of its dims' sizes) is over the cap (200,000 records); it is not flattened. On screen: "{who}: too many subscript elements" | [`subscripts`](../model-file/subscripts.md) |
| <span id="e_subscript_unknown"></span>`E_SUBSCRIPT_UNKNOWN` | error | A record's "dims" is not a list of declared subscript names. On screen: "{who}: unknown subscript {unknown}" | [`subscripts`](../model-file/subscripts.md) |
| <span id="e_table_keys"></span>`E_TABLE_KEYS` | error | A TABLE(...) call passes the wrong number of keys for that table. On screen: "{block}: table {name} takes {need} keys, got {got}" | [`tables`](../model-file/tables.md) |
| <span id="e_table_mode"></span>`E_TABLE_MODE` | error | A lookup mode is unknown, or step/linear was asked for on non-numeric keys. On screen: "Table {name}: unknown lookup mode {mode}" / "Table {name}: lookup mode {mode} needs numeric keys" | [`tables`](../model-file/tables.md) |
| <span id="e_table_name"></span>`E_TABLE_NAME` | error | A table has an empty or duplicate name. On screen: "A table has no name" / "Table {name} is defined twice" | [`tables`](../model-file/tables.md) |
| <span id="e_table_shape"></span>`E_TABLE_SHAPE` | error | A table's keys/columns/values do not form a rectangle, or repeat a key. On screen: "Table {name}: keys must be a non-empty list" / "Table {name} has a repeated key" / "Table {name}: keys and value rows differ in number" / "Table {name}: columns must be a non-empty list" / "Table {name} has a repeated column" / "Table {name}: row {row} has the wrong number of values" | [`tables`](../model-file/tables.md) |
| <span id="e_table_unknown"></span>`E_TABLE_UNKNOWN` | error | A TABLE("name", ...) call names a table the model does not declare. On screen: "{block}: unknown table {name}" | [`tables`](../model-file/tables.md) |
| <span id="e_table_value"></span>`E_TABLE_VALUE` | error | A table value (or its default) is not a number. On screen: "Table {name}: default {value} is not a number" / "Table {name}: value {value} is not a number" | [`tables`](../model-file/tables.md) |
| <span id="e_time_unit"></span>`E_TIME_UNIT` | error | A time_unit is neither "base" nor one of the known units. On screen: "{where}: unknown time unit {unit}" / "The model's time unit {unit} is not known" | -- |
| <span id="e_transfer_mode"></span>`E_TRANSFER_MODE` | error | A TRANSFER block's or an agent transfer action's mode is neither "remove" nor "add". On screen: "Agent type {agent}: {where}: transfer mode must be remove or add" / "Block {block}: unknown transfer mode {mode}" | [TRANSFER](../blocks/transfer.md) |
| <span id="e_undeclared_variable"></span>`E_UNDECLARED_VARIABLE` | error | An expression or ASSIGN target names a variable the model does not declare. On screen: "Block {block}: variable {variable} is not declared" / "Block {block}: power variable {variable} is not declared" | [ASSIGN](../blocks/assign.md), [`variables`](../model-file/variables.md) |
| <span id="e_unit"></span>`E_UNIT` | error | A unit is not one of its quantity's units (length, speed, mass, energy, power). On screen: "{where}: unknown unit {unit}" / "The model's length unit {unit} is not known" | -- |
| <span id="e_unit_mismatch"></span>`E_UNIT_MISMATCH` | error | `simulation.sd.units == "strict"`: same condition as W_UNIT_MISMATCH, reported as an error instead. On screen: "{block}: unit {a} does not match {b}" / "{block}: its expression adds unlike units" | -- |
| <span id="e_unit_time"></span>`E_UNIT_TIME` | error | `simulation.sd.units == "strict"`: same condition as W_UNIT_TIME, reported as an error instead. On screen: "{block}: {a} and {b} differ in time scale" | -- |
| <span id="e_variable_name"></span>`E_VARIABLE_NAME` | error | A variable name is not a Python identifier. On screen: "Variable {name} is not a valid name" | [`variables`](../model-file/variables.md) |
| <span id="e_variable_reserved"></span>`E_VARIABLE_RESERVED` | error | A variable name shadows a reserved name or a built-in function. On screen: "Variable {name} uses a reserved name" | [`variables`](../model-file/variables.md) |
| <span id="e_variable_unknown"></span>`E_VARIABLE_UNKNOWN` | error | A VAR("name") call names a variable the model does not declare . On screen: "{block}: no variable named {name}" | [`variables`](../model-file/variables.md) |
| <span id="w_blocking_loop"></span>`W_BLOCKING_LOOP` | warning | A closed loop of finite buffers can deadlock: every station in it could end up holding a part with nowhere to put it. On screen: "Finite buffers form a closed loop: {chain}" | -- |
| <span id="w_conveyor_handed_to_nothing"></span>`W_CONVEYOR_HANDED_TO_NOTHING` | warning | In the run, a part reached a CONVEYOR's end (or a reversible belt's start) with no next block; it stands there and the belt is blocked, so a run that drains ends with a deadlock naming it. Warned once per belt; an error that stops the run under simulation.strict_checks. On screen: "A part reached a belt exit with no next block" | [CONVEYOR](../blocks/conveyor.md) |
| <span id="w_conveyor_level_key"></span>`W_CONVEYOR_LEVEL_KEY` | warning | A conveyor level sets capacity/min/max_inflow/max_outflow, which a conveyor ignores (its own conveyor.capacity/in_limit apply). On screen: "Conveyor {name}: level limits are ignored" | [CONVEYOR](../blocks/conveyor.md), [`levels`](../model-file/levels.md) |
| <span id="w_conveyor_open_port"></span>`W_CONVEYOR_OPEN_PORT` | warning | A conveyor piece on the floor (a CONVEYOR with a path, or a CONVEYOR_TRANSFER's exit) has a port no link joins: a belt's in, out or divert port d&lt;k&gt;, a transfer's exit port. An area link counts as a link. An error under simulation.strict_checks. On screen: "Belt {block}: port {port} is open" / "Transfer {block}: exit {port} is open" | [CONVEYOR](../blocks/conveyor.md), [CONVEYOR_TRANSFER](../blocks/conveyor-transfer.md) |
| <span id="w_conveyor_overlap"></span>`W_CONVEYOR_OVERLAP` | warning | Two CONVEYORs with a path overlap on the floor plan, each piece a flat-ended strip its width across (an untyped belt is 0.8 m wide); two pieces that meet at a joint (port to port, a divert, a merge or one transfer) skip one belt width around it. The first 20 pairs are listed, then a count. An error under simulation.strict_checks. On screen: "Belt {block} overlaps belt {other}" / "{count} more pairs of belts overlap" | [CONVEYOR](../blocks/conveyor.md) |
| <span id="w_conveyor_snap"></span>`W_CONVEYOR_SNAP` | warning | A link joins two CONVEYORs with a path whose ports are more than 0.05 m or 5 degrees apart on the floor plan. An error under simulation.strict_checks. On screen: "Belt {block}: port {port} does not meet {target}" | [CONVEYOR](../blocks/conveyor.md) |
| <span id="w_conveyor_stop_held"></span>`W_CONVEYOR_STOP_HELD` | warning | A CONVEYOR stop seizes a resource a part still holds when it gets there (seized upstream, not yet released); the run stops with an error when a part asks for it twice. On screen: "Block {block}: stop {index} seizes {resource}, already held" | [CONVEYOR](../blocks/conveyor.md) |
| <span id="w_conveyor_transit"></span>`W_CONVEYOR_TRANSIT` | warning | A literal transit_time is not a multiple of dt; the belt has round(T/dt) slats. On screen: "Conveyor {name}: transit time is not a multiple of the step" | [CONVEYOR](../blocks/conveyor.md) |
| <span id="w_flow_clock_no_grid"></span>`W_FLOW_CLOCK_NO_GRID` | warning | A flow rate reads TNOW in a model with no simulation.sd step grid, so the clock is only read at events. On screen: "Flow {name}: rate reads the clock but there is no time step" | [`flows`](../model-file/flows.md) |
| <span id="w_loop_hybrid"></span>`W_LOOP_HYBRID` | warning | Loop dominance on a model with DES blocks or agent populations: the variables they write are read at their initial values (SD layer only). | -- |
| <span id="w_rate_unit_changed"></span>`W_RATE_UNIT_CHANGED` | warning | Since 0.10.0 a flow's peak_price, thresholds and reported rates, and a conversion's CONV() and rates, are per their own time unit, not the base one. On screen: "Flow {name}: rates are now per {unit}, not per {base}" / "Conversion {name}: rates are now per {unit}, not per {base}" | -- |
| <span id="w_rate_unit_read"></span>`W_RATE_UNIT_READ` | warning | A flow rate or a conversion feed reads FLOW(), FLOWSUM() or CONV() of a rate written per another time unit, and takes it unconverted. On screen: "{who}: {call} is in another time unit, read unconverted" | -- |
| <span id="w_rate_unit_unchecked"></span>`W_RATE_UNIT_UNCHECKED` | warning | A flow rate or a conversion feed reads FLOW(), FLOWSUM() or CONV() of a computed name, and the records it may read are per different time units, so the read cannot be unit-checked. On screen: "{who}: {call} reads names in different time units" | -- |
| <span id="w_ref_unset"></span>`W_REF_UNSET` | warning | A POWER(), TS() or other named read takes its name from an asset parameter left empty, so the run would fail on it. On screen: "{block}: {func}() reads {name}, which is empty" | -- |
| <span id="w_sd_rk4_bus"></span>`W_SD_RK4_BUS` | warning | A dynamic flow rate reads FLOW()/FLOWSUM() under RK4, whose stages ignore saturation. On screen: "Flow {name}: Runge-Kutta reads rates from the step start" | [`simulation`](../model-file/simulation.md) |
| <span id="w_series_before_start"></span>`W_SERIES_BEFORE_START` | warning | A dated time series starts before, or ends after, the run window. On screen: "Time series {name} starts before the calendar start" / "Time series {name}: every sample is after the run ends" | [`timeseries_inputs`](../model-file/timeseries_inputs.md) |
| <span id="w_series_period_unused"></span>`W_SERIES_PERIOD_UNUSED` | warning | A time series has a period but does not repeat, so the period is never read. On screen: "Time series {name}: period has no effect without repeat" | [`timeseries_inputs`](../model-file/timeseries_inputs.md) |
| <span id="w_unit_mismatch"></span>`W_UNIT_MISMATCH` | warning | A level/flow/auxiliary's declared or inferred unit does not match another unit it should agree with (expected vs found). On screen: "{block}: unit {a} does not match {b}" / "{block}: its expression adds unlike units" | -- |
| <span id="w_unit_missing"></span>`W_UNIT_MISSING` | warning | `simulation.sd.units == "strict"`: a level or flow declares no unit at all. On screen: "Level {block}: no unit declared" / "Flow {block}: no unit declared" | -- |
| <span id="w_unit_time"></span>`W_UNIT_TIME` | warning | A unit matches dimensionally but uses a different time scale than the model's base time unit (e.g. people/hour feeding a level in days). On screen: "{block}: {a} and {b} differ in time scale" | -- |
| <span id="w_unit_unparsed"></span>`W_UNIT_UNPARSED` | warning | A declared `unit` string could not be parsed. On screen: "{block}: unit {unit} could not be read" | -- |

## How to fix

Each code with the usual remedy:

- `E_ASSIGN_KEY`: Give each entry in the ASSIGN block's `assignments` only the keys `target` and `expr`. A misspelt key, such as `value` for `expr`, is otherwise dropped; rename or remove it.
- `E_ASSIGN_TARGET`: Set the ASSIGN target to `entity.<attribute>`, `entity.agent.<attribute>` or the name of a declared variable. Other forms, such as a function call, cannot be written to.
- `E_AUX_CYCLE`: Break the loop the message lists in `auxiliaries`: make one of those auxiliaries read a level (a stock) or a delay instead of another auxiliary in the cycle.
- `E_AUX_NAME`: Give every entry in `auxiliaries` a non-empty `name`, and rename one of any two auxiliaries that share a name.
- `E_AUX_UNKNOWN`: Declare the auxiliary in the `auxiliaries` section, or correct the name in the `AUX("...")` call. Names are case sensitive.
- `E_BUFFER_LEVEL`: Declare the level named in the BUFFER's `level` parameter in the `levels` section, correct the name, or clear the `level` field.
- `E_CHARGE`: On the CHARGE block, set `sharing` to `equal` or `first_come` and `efficiency` to a number above 0 and at most 1. If `leave_when_full` is false, also set a `time_limit`.
- `E_CONVERSION_CURVE`: Fix the substrate in `conversions.<name>.substrates`: set `yield` to a number of 0 or more. Give either a positive `half_life` or a `curve` of `[age, cumulative fraction]` knots with increasing ages that ends at `1.0`.
- `E_CONVERSION_INTERVAL`: Set the conversion's `cohort_interval` to a positive number, or leave it out for the default of 1.
- `E_CONVERSION_NAME`: Make every entry in `conversions` an object with a non-empty `name`, and rename one of any two conversions that share a name.
- `E_CONVERSION_SUBSTRATE`: Give the conversion at least one entry in `substrates`, each with a non-empty `name`, and rename one of any two substrates that share a name.
- `E_CONVERSION_UNKNOWN`: Declare the conversion in the `conversions` section, or correct the name in the `CONV("...")` call. Names are case sensitive.
- `E_CONVEYOR_DIVERT`: Write each divert as `at`, `condition` and optionally `time` and `when_full`, with `at` on the belt. Give the belt one more link than it has diverts.
- `E_CONVEYOR_GRID`: Add the system-dynamics grid to the model, for example `"simulation": {"sd": {"dt": 0.25}}`, or remove `conveyor` from the level.
- `E_CONVEYOR_LEAK`: Set the leak flow's `from` to a conveyor level, give its `leak` a `fraction`, and keep `zone` as `[start, end]` with `0 <= start < end <= 1`. Otherwise drop `leak` from the flow.
- `E_CONVEYOR_MERGE`: Write each merge as `at`, `from` and optionally `priority`, with `at` on the belt and `from` naming a block that links to the belt. Merges need an accumulating belt.
- `E_CONVEYOR_METHOD`: Set `simulation.sd.method` to `euler`, or remove the conveyor. A conveyor moves one slat per DT, which `rk4` cannot do.
- `E_CONVEYOR_OUTFLOW`: Give the conveyor exactly one outflow without `leak` and mark the other outflows with `leak`. Set that primary outflow's `rate` to empty, since it takes what leaves the belt.
- `E_CONVEYOR_PARAM`: On the CONVEYOR block, set `speed` and `spacing` to positive numbers and `length` to a number of 0 or more. With no `length`, set both `from_node` and `to_node` to declared `network` nodes; declare any `exit_resource` under `resources`.
- `E_CONVEYOR_SPEC`: Give the conveyor level a `conveyor.transit_time` (a number or an expression), and set `leak_kind` to one of the kinds the hint lists, or leave it out.
- `E_CONVEYOR_STOP`: Write each entry of the CONVEYOR's `stops` as `{at, time, resource}` only, with `at` between 0 and `length` (both excluded). Make `time` a number of 0 or more or an expression, and declare any `resource` under `resources`.
- `E_CONVEYOR_WRITE`: Do not write a conveyor level directly. Point the TRANSFER, agent transfer action or BUFFER `level` at an ordinary level, drop it from `initial_state.levels`, and give each element its own conveyor instead of `dims`.
- `E_DASHBOARD_SERIES`: Give a `kpi` or `gauge` widget an `expr` and no `series`. Give a `line` widget 1-4 and a `bar` widget 1-8 `series` entries, each with a unique non-empty `label`, and no `expr`.
- `E_DELAY_NAME`: Give every entry in `delays` a non-empty `name`. Rename one of any two delays that share a name, or whose hidden stage names clash, such as `f` and the inline `f#1`.
- `E_DELAY_SPEC`: Set the delay's `kind` to a known kind and fill in its required fields (`input` and `delay_time` for most kinds). A numeric `delay_time` must be greater than 0.
- `E_DELAY_UNKNOWN`: Declare the delay in the `delays` section, or correct the name in the `DELAY("...")` call. Names are case sensitive.
- `E_DUPLICATE_REALITY_CHECK`: Rename one of the two entries in `reality_checks` that share a name. Each reality check needs a unique `name`.
- `E_DUPLICATE_VARIABLE`: Rename one of the two entries in `variables` that share a name, or delete the duplicate. Expressions and overrides refer to a variable by its name.
- `E_ENERGY_PRICE`: Set `simulation.energy_price` to a number, such as `0.18` money per kWh, or to an expression over declared variables that compiles.
- `E_EXPRESSION`: Rewrite the expression within the allowed grammar. Check the function names for case (`max`, not `MAX`), use positional arguments only, and quote string arguments such as table names.
- `E_FIXED_COST_AMOUNT`: Set the fixed cost's `amount` to a number, or to an expression over variables and model data that compiles, such as `capacity_kwh * 600`.
- `E_FIXED_COST_NAME`: Make every entry in `fixed_costs` an object with a non-empty `name`, and rename one of any two fixed costs that share a name.
- `E_FLOW_BIFLOW`: Set the flow's `biflow` to `true` or `false`. For a bi-directional flow, give the levels it joins `"min": null` and no capacity or power limit, or split it into two one-way flows.
- `E_FLOW_COMPONENT`: Set the flow's `components` to an object of component name to share, such as `{"ch4": 0.52}`, or leave it out to carry the source level's own blend.
- `E_FLOW_EFFICIENCY`: Set the flow's `efficiency` to a number above 0 and at most 1, or leave it out for a lossless flow.
- `E_FLOW_LEVEL`: Set the flow's `from` and `to` to levels declared in `levels`, or leave the field out for a source or sink outside the model.
- `E_FLOW_MIN_RATE`: Set the flow's `min_rate` to a number of 0 or more, or leave it out.
- `E_FLOW_NAME`: Give every entry in `flows` a non-empty `name`, and rename one of any two flows that share a name.
- `E_FLOW_PEAK_PRICE`: Set the flow's `peak_price` to a number (money per unit of peak rate), or leave it out. A time-varying tariff goes in `price`.
- `E_FLOW_TAG`: Set the flow's `tag` to a string and its `priority` to a number. Give every flow that shares a tag the same `rate_time_unit`.
- `E_FLOW_THRESHOLD`: Give each entry in the flow's `thresholds` a numeric `value`, a `direction` of `falling`, `rising` or `both`, and a numeric `cost` if any.
- `E_FLOW_UNKNOWN`: Declare the flow in the `flows` section, or correct the name in the `FLOW("...")` call. Names are case sensitive.
- `E_LEVEL_BOUNDS`: Give the level's `capacity`, `min`, `initial`, `max_inflow` and `max_outflow` numeric values, keep `capacity` at or above `min`, and start `initial` inside them. A value in `initial_state.levels` must be a number.
- `E_LEVEL_COMPONENT`: Give each of the level's `components` a unique non-empty `name` and an `initial_fraction` between 0 and 1, and set `blend_tolerance` to a positive number.
- `E_LEVEL_NAME`: Give every entry in `levels` a non-empty `name`, and rename one of any two levels that share a name.
- `E_LEVEL_THRESHOLD`: Give each entry in the level's `thresholds` a numeric `value`, a `direction` of `falling`, `rising` or `both`, and a numeric `cost` if any.
- `E_LEVEL_UNKNOWN`: Declare the level in the `levels` section, or correct the name in the `LEVEL("...")` call, the TRANSFER's `level`, the agent's transfer action or `initial_state.levels`.
- `E_LOG_LEVEL`: Set `simulation.log_level` to one of the levels `kpi`, `series` or `full`, or to a profile: `study`, `explore` or `replay`. Remove it to let `record_logs` and `timeseries_points` decide.
- `E_LOOP_GRID`: Add the system-dynamics grid before asking for loop dominance, for example `"simulation": {"sd": {"dt": 0.25, "method": "euler"}}`.
- `E_POWER_UNKNOWN`: Declare the name in `resources`, `fleets` or `chargers`, or correct the name in the `POWER("...")` call. Names are case sensitive.
- `E_REALITY_CHECK_INPUT`: Set the reality check's `inputs` to an object of override path to value, such as `{"auxiliaries.Workforce.expr": "0"}`, with no empty path.
- `E_REALITY_CHECK_NAME`: Give every entry in `reality_checks` a non-empty `name`.
- `E_REALITY_CHECK_WHEN`: Set the reality check's `when` to `always`, `final`, `after <t>`, `before <t>`, `between <t1> and <t2>` (t1 not after t2), or `eventually`, alone or before one of those windows.
- `E_SD_DELAY_ORDER`: Give the delay's `order` as a literal integer of 1 or more, such as `DELAYN(x, tau, 3)`. The number of stages is fixed when the model is built, so an expression or a fraction cannot set it.
- `E_SD_FUNCTION_CONTEXT`: Move the SMOOTH or DELAY call into a level's initial value, a flow rate, an auxiliary or a delay field. Read its result in the block or price with `AUX()`, `LEVEL()` or `DELAY()`.
- `E_SD_REQUIRES_DT`: Add a step grid, such as `"simulation": {"sd": {"dt": 0.25}}`, since material and information delays integrate hidden stocks. Or use a pipeline delay (`DELAYP`), which is exact without one.
- `E_SD_RK4_RANDOM`: Set `simulation.sd.method` to `euler`, or move the random draw out of the flow rate into a variable an ASSIGN sets. RK4 evaluates a dynamic rate four times per step.
- `E_SD_SETTINGS`: Make `simulation.sd` an object with a numeric `dt` above 0, a `method` from the listed ones and a `time_unit` of `base` or a known unit. Remove any other key, such as a misspelt one.
- `E_SERIES_MODE`: Set the series' `interpolation` and `beyond` to one of the values the hint lists. A text `period` must be `daily`, `weekly` or `yearly`; otherwise give a number.
- `E_SERIES_NAME`: Give every entry in `timeseries_inputs` a non-empty `name`, and rename one of two series that share a name. `TS()` calls find a series by its name.
- `E_SERIES_NO_CALENDAR`: Add `simulation.calendar` with a `start` (and a `timezone`) so real timestamps can be placed on the model clock. Or give the series plain numeric `times` instead.
- `E_SERIES_SHAPE`: Give the series one value per sample and either `times` or a `step`, not both. The sample count must match, and the times must increase.
- `E_SERIES_UNKNOWN`: Declare the series under `timeseries_inputs`, or correct the name in the `TS("name")` call. Names are case sensitive.
- `E_SUBSCRIPT_AGGREGATE`: Write a one-argument `SUM(x)` or `MEAN(x)` over a `[*]` index, such as `SUM(LEVEL("Pop[*]"))`, in a level, flow, auxiliary or delay. Read the result elsewhere with `AUX()`.
- `E_SUBSCRIPT_DIM`: Give the record the `dims` its `[dim]` indexes name, list each dimension once, and keep `[*]` inside SUM or MEAN. A flow joining a subscripted level needs that level's `dims`.
- `E_SUBSCRIPT_ELEMENT`: Make the record's `elements` an object keyed by element combinations of its own `dims`. Remove or rename overrides whose key matches no element.
- `E_SUBSCRIPT_MAP`: Point the subscript's `map_to` at another declared subscript. Give `elements` one target element per element, or make both subscripts the same size so they map by position.
- `E_SUBSCRIPT_NAME`: Give each entry in `subscripts` a unique identifier as `name` and a non-empty list of unique `elements`. Elements may not hold `[`, `]`, `,` or `*`, nor share a subscript's name.
- `E_SUBSCRIPT_RANGE`: Set the subscript's `parent` to another declared subscript that holds every one of its elements, or remove `parent`. Add any missing elements to the parent first.
- `E_SUBSCRIPT_SIZE`: Use fewer or smaller dimensions in the record's `dims`. The product of their element counts must stay within the 200,000 cap.
- `E_SUBSCRIPT_UNKNOWN`: Make the record's `dims` a list of names declared under `subscripts`, or declare the missing subscript there. The hint lists the declared ones.
- `E_TABLE_KEYS`: Pass as many keys as the table has axes: one for a 1-D table, two for a table with `columns`, such as `TABLE("name", k1, k2)`.
- `E_TABLE_MODE`: Set the table's `key_mode` or `column_mode` to one of the listed lookup modes. Use `exact` for text keys, since `step` and `linear` interpolate only numeric keys.
- `E_TABLE_NAME`: Give every entry in `tables` a non-empty `name`, and rename one of two tables that share a name. `TABLE()` calls find a table by its name.
- `E_TABLE_SHAPE`: Make the table a rectangle. A 1-D table needs one value per key. A 2-D table needs one row of values per key, each as long as `columns`, and no key may repeat.
- `E_TABLE_UNKNOWN`: Declare the table under `tables`, or correct the name in the `TABLE("name", ...)` call. The hint lists the declared tables.
- `E_TABLE_VALUE`: Make every cell in the table's `values` a number, and make `default` a number or drop it. Text such as `"5"` is not accepted.
- `E_TIME_UNIT`: Set the named `time_unit` (or rate unit key) to one of the known time units, such as `minutes` or `hours`. A block or record field may also take `base`, the model's own unit.
- `E_TRANSFER_MODE`: Set the TRANSFER block's or the agent transfer action's `mode` to `remove` or `add`.
- `E_UNDECLARED_VARIABLE`: Declare the variable in the `variables` section, or correct the name in the expression or ASSIGN target. Names are case sensitive.
- `E_UNIT`: Set the unit key, such as `simulation.length_unit` or a field's unit, to one of its quantity's units. A record field may also take `base`; the hint names the quantity.
- `E_UNIT_MISMATCH`: Correct the `unit` of the level, flow or auxiliary, or the expression, so expected and found units agree. Or set `simulation.sd.units` to `warn` to report it as a warning only.
- `E_UNIT_TIME`: Write the rate in the model's base time unit, or correct the record's `unit` so the time scales match. Or set `simulation.sd.units` to `warn` to report it as a warning only.
- `E_VARIABLE_NAME`: Rename the variable to a Python identifier: letters, digits and `_`, not starting with a digit. Update every expression and ASSIGN that uses it.
- `E_VARIABLE_RESERVED`: Rename the variable so it does not shadow a reserved name or built-in function, such as `min` or `TNOW`. The hint lists the reserved names.
- `E_VARIABLE_UNKNOWN`: Declare the variable under `variables`, or correct the name in the `VAR("name")` call. Names are case sensitive.
- `W_BLOCKING_LOOP`: Give one buffer in the loop enough places that it never fills, or route one station's output to a block with an unlimited queue. If the loop can never fill, the warning can stay.
- `W_CONVEYOR_LEVEL_KEY`: Remove `capacity`, `min`, `max_inflow` and `max_outflow` from the conveyor level. Set its content limit with `conveyor.capacity` and its inflow per time unit with `conveyor.in_limit`.
- `W_CONVEYOR_STOP_HELD`: Release the resource before the part enters the belt, or remove the stop's `resource`, since the part already holds it. Otherwise the run stops with an error at that stop.
- `W_CONVEYOR_TRANSIT`: Pick a `simulation.sd.dt` that divides the conveyor's `transit_time`, or change the transit time to a multiple of `dt`. Otherwise the belt runs with round(T/dt) slats.
- `W_FLOW_CLOCK_NO_GRID`: Read a timetable from a `timeseries_inputs` entry with `TS("name")`, `interpolation` `step` and `beyond` `repeat`. Or add a step grid with `simulation.sd.dt`; each switch is then late by up to `dt`.
- `W_LOOP_HYBRID`: Treat the scores as covering the SD layer only, since DES blocks and agents are read at initial values. Run `naga loops` on an SD-only model to score every loop; otherwise the warning can stay.
- `W_RATE_UNIT_CHANGED`: Check that the flow's `peak_price` and `thresholds` are per its `rate_time_unit`, and a conversion's numbers per its `time_unit`. Rescale values written per the base unit; if already right, the warning can stay.
- `W_RATE_UNIT_READ`: Give the reading rate and the record it reads with `FLOW()`, `FLOWSUM()` or `CONV()` the same time unit. Or convert the value in the expression.
- `W_RATE_UNIT_UNCHECKED`: Write the name in the `FLOW()`, `FLOWSUM()` or `CONV()` call as a literal, or give every record it may read the same time unit. Then the read can be unit-checked.
- `W_REF_UNSET`: Set the asset parameter that the `POWER()` or `TS()` call takes its name from to the source or series it should read. Or guard the read with a condition on that parameter.
- `W_SD_RK4_BUS`: Set `simulation.sd.method` to `euler` for exact `FLOW()` and `FLOWSUM()` reads. Under RK4 the read lags by one stage; if that is acceptable, the warning can stay.
- `W_SERIES_BEFORE_START`: Check the series' dates against `simulation.calendar.start` and the run length. Trim or shift samples before the start, or a series whose samples all fall after the run ends.
- `W_SERIES_PERIOD_UNUSED`: Add `"beyond": "repeat"` to the series so it cycles every `period`, or drop `period`. Without repeat the series holds its last value.
- `W_UNIT_MISMATCH`: Correct the `unit` of the level, flow or auxiliary, or its expression, so the expected and found units agree. If the mismatch is intended, set `simulation.sd.units` to `off`.
- `W_UNIT_MISSING`: Add a `unit` to the level or flow, such as `people` or `people/day`, so mismatches can be checked. Or set `simulation.sd.units` to `warn`.
- `W_UNIT_TIME`: Write the rate's `unit` in the model's base time unit, such as `people/day` for levels counted per day. If the scaling is intended, the warning can stay.
- `W_UNIT_UNPARSED`: Rewrite the `unit` string in a form the unit parser reads, such as `kg`, `people/day` or `m/s`. Until then the record is not unit-checked.

[All problem codes](index.md)