levels¶
Continuous quantities with bounds (battery energy, tank volume, an inventory position), read by LEVEL("name").
In the model file this key holds a list of level entries, each named by its name.
A scenario, an experiment or an optimizer can set a field by the path levels.<name>.<field>.
Typical uses¶
These sections model quantities that change continuously: a tank, a battery, a stock, an energy bus. A level is the quantity with its bounds. A flow moves it at a rate. A conversion turns a feed into a product that is released later, such as biogas from feedstock. Use them when counting entities is the wrong view.
Behaviour and rules¶
A flow rate is an expression that is re-evaluated only at events, so it is constant between them. Every level is then a straight line between events, and the engine solves for the instant a level reaches a bound or a threshold. There is no fixed time step unless simulation.sd asks for one.
The engine enforces the bounds. A level at its min passes on no more than flows into it, and a full level scales its inflows down. What is lost is recorded as unmet for demand not served and as spilled for overflow. A rate needs no guard for an empty level. A negative rate is clamped to 0 unless the flow is a biflow.
A price is money per unit moved and an emission_factor is an impact per unit. Both are integrated exactly. A peak_price is a demand charge, billed once at the end of the run. A flow with a tag is summed by FLOWSUM("tag"), which is how many assets share one site bus.
A TRANSFER block moves a lump between an entity and a level. A conversion releases its product after a delay that follows a yield curve, in cohorts closed every cohort_interval.
Fields¶
| Field | Type | Required | Default | Unit | Description |
|---|---|---|---|---|---|
diagram |
object | Position in the stock-and-flow view; ignored by the engine. | |||
name |
string | yes | The level's name, the argument of LEVEL("name"). | ||
dims |
list of string | Subscripts this record runs over: it is flattened into one record per element, named "Name[north]" ("Name[north,young]" for two). Inside, "x[dim]" in a LEVEL/FLOW/AUX/DELAY name reads the same element, and SUM(x)/MEAN(x) aggregate over "x[*]". | |||
elements |
object | Per-element equations: {"north": "2", "a,x": "3"} replaces the record's first expression (a level's initial, a flow's rate, an auxiliary's expr, a delay's input) for those elements; the shared one covers the rest. Keys join one element per dim with a comma. | |||
description |
string | What the level stands for; the run does not read it. | |||
unit |
string | Label only, e.g. kWh or tonnes. | |||
capacity |
number or null | Upper bound; omit for an unbounded accumulator. | |||
min |
number or null | 0.0 |
Lower bound; null for a stock unbounded below . | ||
initial |
number or string | 0.0 |
Value at t=0, inside [min, capacity]; or an expression, evaluated once in dependency order . | ||
max_inflow |
number or null | rate (rate_time_unit) |
Largest total rate that may be ADDED to the level (a charge-power limit). | ||
max_outflow |
number or null | rate (rate_time_unit) |
Largest total rate that may be REMOVED from it (a discharge-power limit). | ||
rate_time_unit |
choice | "base" |
Unit the two power limits are per. One of base, milliseconds, seconds, minutes, hours, days, weeks, months, years. |
||
thresholds |
list of object | Level values that fire discrete logic when crossed. | |||
components |
list of object | Named components the level's content is tracked in: a gas holder's ch4. Each inflow carries a share, each outflow draws at the level's own blend, and the component is conserved exactly. Read by FRACTION(name, component). | |||
blend_tolerance |
number | 0.005 |
ratio | How far the fraction may drift from the value the outflows are drawing at before the engine re-evaluates. The crossing instant is solved in closed form; the component is conserved exactly whatever this is set to. | |
storage |
object | A storage the dispatch plan may drive: its power limits, efficiencies and the variable the plan writes its bus-side setpoint to (positive charges). Rates are per this level's rate_time_unit. Inert without a dispatch section. |
|||
conveyor |
object | Makes the stock a Stella conveyor: material rides round(transit_time/dt) slats of the SD grid (euler only), leaves as the one primary outflow (rate "") and may leak on the way through "leak" flows. The stock is the sum of the slats and changes only at grid points. | |||
locals |
object | Submodel parameter bindings, written by flattening; not authored by hand. |
A field of a nested object is described in the JSON Schema (naga schema).
Example¶
{"levels": [{"name": "Tank", "capacity": 100, "initial": 40}]}
In the Python builder:
from nagasim import build as nb
m = nb.Model()
m.add_level(name='Tank', capacity=100, initial=40)
Used in¶
Bundled models: Biogas digester, holder and CHP, Biogas plant (library assets), Depot: PV, EV charging and heat pump, PV + battery sizing and dispatch, PV + battery site (library assets), Supply line: order-rate management game and 11 more.
Guides: Continuous quantities: levels, flows and time-series inputs, Coming from AnyLogic, Coming from Vensim, How do I turn a heading and a distance into x and y?, How do I add a daily or weekly cycle to a rate?, How do I discount a stream of cash? and 10 more.