Skip to content

Problem codes: Data, live feeds and the twin

Data sources and bindings, network access limits, live feeds, warm starts, saved states, plant mappings, the twin cycle and the MES. The list is generated from the codes' own table; the meaning is the table's sentence for the code.

Code Severity Meaning About
E_CANDIDATES error A candidates file is not one of format 1, is over its bound, holds a key or an action it may not, or names what the model does not declare. On screen: "The candidate actions are not valid" --
E_CANDIDATE_VERB error A candidate's verb is not one of the vocabulary's verbs. On screen: "A candidate action is not one the twin knows" --
E_CONN_FORMAT error The caller's connections file is malformed, or asks for something refused. On screen: "The connections file is not valid" --
E_DATA_BINDING_NAME error A binding has an empty or duplicate name. On screen: "A data binding has no name" / "Data binding {name} is defined twice" data_bindings
E_DATA_BINDING_SOURCE error A binding names a data source the model does not declare. On screen: "Binding {name}: unknown data source {source}" data_bindings
E_DATA_BINDING_TARGET error A binding's target is not an override path this model has. On screen: "Binding {name}: target is empty" / "Binding {name}: column is empty" data_bindings
E_DATA_BINDING_TRANSFORM error A binding's transform is not a known one. On screen: "Binding {name}: unknown transform {transform}" data_bindings
E_DATA_CONNECTION error A live source names no connection, or one its caller did not define for it. On screen: "Data source {name}: a {kind} source needs a connection" --
E_DATA_CREDENTIALS error A source URL embeds a password; read it from ${NAGASIM_DATA_<NAME>} instead. On screen: "Data source {name}: the location holds a password" --
E_DATA_EMPTY error A binding's column held no usable value after filtering. On screen: "{source}: no usable value" --
E_DATA_ENV error A ${NAGASIM_DATA_<NAME>} reference names an environment variable that is not set. On screen: "{source}: a setting it needs is not set" --
E_DATA_ENV_NAME error A ${NAME} reference names a variable a model file may not read: only names starting with NAGASIM_DATA_ are expanded. On screen: "{source}: names a setting it may not read" --
E_DATA_FILTER error A binding's filter is not a simple {column op value} mapping. On screen: "Binding {name}: filter must be an object" / "Binding {name}: bad filter key {key}" --
E_DATA_NETWORK_REFUSED error A network source was refused: no human granted network access. On screen: "{source}: network access not granted" network
E_DATA_PATH_OUTSIDE_ROOT error A source path escapes the root the caller confined it to. On screen: "{source}: its file is outside the allowed folder" --
E_DATA_PLAINTEXT_CREDENTIAL error A connection would send its credential over a channel that is not encrypted, to another machine. On screen: "{source}: would send a password unencrypted" --
E_DATA_PROXY error A fetch through the caller's proxy was refused: plain http, or the proxy did not open the tunnel. On screen: "{source}: the proxy refused the connection" --
E_DATA_QUERY error A source's query is not one SELECT statement. On screen: "{source}: its query is not a single read" --
E_DATA_READ error A data source could not be read (missing file, bad query, unreachable URL). On screen: "{source} cannot be read" --
E_DATA_SOURCE_KIND error A data source's kind is not one the engine reads. On screen: "Data source {name}: unknown kind {kind}" data_sources
E_DATA_SOURCE_LOCATION error A data source has no location, or none its kind can use. On screen: "Data source {name}: location is empty" / "Data source {name}: a {kind} source needs a query" / "Data source {name}: location must not name a host" data_sources
E_DATA_SOURCE_NAME error A data source has an empty or duplicate name. On screen: "A data source has no name" / "Data source {name} is defined twice" data_sources
E_DATA_SOURCE_OPTION error A live source carries an option its reader does not know, or a value the option cannot take. On screen: "Data source {name}: unknown option {key}" data_sources
E_DATA_TLS error A connection's TLS handshake failed: the certificate is not valid for the host. On screen: "{source}: its certificate is not valid" --
E_DATA_TOO_LARGE error A fetched response is over the size cap. On screen: "{source}: the answer is too large" --
E_DATA_TYPE error A binding's resulting value does not match the type the target holds. On screen: "{source}: a value has the wrong type" --
E_DATA_URL_HOST error A source URL has no usable hostname, or one outside the allowed hosts. On screen: "{source}: its host is not allowed" --
E_DATA_URL_PARAMETER error A database URL carries a query parameter a model file may not set. On screen: "{source}: its address sets a forbidden option" --
E_DATA_URL_PRIVATE error A source URL resolves to a loopback, link-local or private address. On screen: "{source}: a private address is not allowed" --
E_DATA_URL_REDIRECT error A fetch redirected too many times, downgraded, or landed somewhere refused. On screen: "{source}: redirected somewhere refused" --
E_DATA_URL_SCHEME error A source URL is not http(s), or is a file masquerading as a database URL. On screen: "{source}: its address type is not allowed" --
E_FLEET_POWER_STATE error A fleet's "power" names a state that is not busy/idle/blocked/down/off_shift. On screen: "Fleet {name}: unknown power state {state}" fleets
E_INITIAL_AGE error An initial-state entry's age is negative or not a number. On screen: "Block {block}: age must be 0 or more" initial_state
E_INITIAL_ARRIVALS error initial_state.arrivals does not give a CREATE block a count and a next time. On screen: "Arrivals of {name}: values are not valid" / "Arrivals of {name}: schedule times are not valid" / "Arrivals of {name} tie; their ranks must differ" CREATE, initial_state
E_INITIAL_BATCH error A formed batch in initial_state does not fit the model: an entry that meets a SEPARATE has no members, or its members are not records of one batch the model can form. On screen: "Block {block}: the entry is a formed batch and needs members" / "Block {name}: the batch members are not valid" BATCH, SEPARATE, initial_state
E_INITIAL_BELT error A part on a belt in initial_state does not fit the model: not one entity at an accumulating CONVEYOR, a stage it does not have, a time on the wrong side of the clock, or more than one part at the belt's end. On screen: "Block {name}: a part on a belt is not valid" / "Belt {block}: a part at its end stop is not carried" / "Belt {block}: the parts at its end do not fit" / "Belt {block}: its times do not fit" / "Belt {block}: a part on it is not valid" / "Belt {block}: states do not carry typed belt parts yet" / "Belt {block}: {n} parts at one point" / "Belt {block}: a part waiting at a stop is not carried" / "Belt {block}: {n} parts in section {section}, room for {room}" CONVEYOR, initial_state
E_INITIAL_BLOCK error An initial-state entry is not an object, names a block the model does not have, or misstates its place, its holder or its attributes. On screen: "Initial state must be an object" / "Initial state: entities must be a list of objects" / "Block {name}: what it carries into the run is not valid" / "Initial state: unknown block {name}" / "Block {block}: entity type or attributes not valid" / "Block {block}: the entity's station must be named" / "Block {block}: transfer amount is not valid" / "Block {block}: place must be true or false" / "Block {block}: the block holding the entity is not valid" initial_state
E_INITIAL_BLOCK_TYPE error An initial-state entry names a block type that cannot hold entities. On screen: "Block {block} cannot hold entities at the start" initial_state
E_INITIAL_BUSY error A resource is reported busy with a number of units the in-service entities do not hold. On screen: "Resource {name}: {busy} busy, but entities in service hold {held}" initial_state
E_INITIAL_CARRIER error An initial_state entry of the carrier type waits at a carrier BATCH: its cut-off cannot be put back. On screen: "Block {block}: a waiting {carrier} cannot be restored" BATCH, initial_state
E_INITIAL_CLOCK error initial_state.clock is not a number >= 0 and before the end of the run. On screen: "Initial state: clock is outside the run" initial_state
E_INITIAL_COUNT error An initial-state entry's count is negative or not an integer. On screen: "Block {block}: count must be a whole number, 0 or more" initial_state
E_INITIAL_CYCLE error A MOTION job mid-cycle in initial_state does not fit the model: a cycle not at a MOTION job in service, a segment it does not have, a time that is no duration of it, or an end beyond the segment in progress. On screen: "Block {block}: only a job in service has a cycle" / "Block {name}: the motion cycle is not valid" MOTION, initial_state
E_INITIAL_FAILURE error initial_state.resources.<name>.failures names a failure the resource does not have, or gives it no next or down_until time. On screen: "Resource {name}: failure {failure} is not valid" failures, initial_state
E_INITIAL_FLEET error initial_state.fleets or an entity's trip does not fit the model: a fleet, a vehicle record, a node, a charger or a stage it does not have. On screen: "The fleet state does not fit the model" fleets, initial_state
E_INITIAL_IN_SERVICE error in_service exceeds the entry's count or the resource's capacity. On screen: "Block {block}: number in service must be 0 or more" / "Block {block}: a {btype} block has no service" / "Block {block}: {in_service} in service, only {count} entities" / "Block {block}: needs {needed} units, capacity is {capacity}" / "Resource {name}: {units} units in service, capacity {capacity}" initial_state
E_INITIAL_KEY error initial_state has a key this engine does not know (a newer engine may have written it): refused rather than ignored. On screen: "Initial state: unknown key {key}" initial_state
E_INITIAL_ORDERS error initial_state.orders names an order the model does not declare, or gives it counters or a completion time that cannot be. On screen: "Initial state: the order book is not valid" / "Order {name}: its counters are not valid" initial_state
E_INITIAL_QUEUE_CAPACITY error More entities wait at a block, or sit in a BUFFER, than it has places. On screen: "Block {block}: {queued} entities wait, queue holds {room}" / "Belt {block}: {n} parts, only {cells} cells" BUFFER, initial_state
E_INITIAL_REMAINING error remaining is not a list of non-negative numbers, or is longer than in_service; or ends, arrives or since is not an absolute time the entry can carry. On screen: "Block {block}: remaining times must be numbers, 0 or more" / "Block {block}: {n} remaining times for {in_service} in service" / "Block {block}: service end times are not valid" / "Block {block}: deadline must be at or after the clock" / "Block {block}: since must be at or before the clock" / "Block {block}: arrival time is not valid" / "Block {block}: the held-since time is not valid" / "Block {block}: the held-since time is not valid" initial_state
E_INITIAL_RESOURCE error initial_state.resources, or an entity's holds, names a resource the model does not declare, or a hold it cannot be. On screen: "Initial state: unknown resource {name}" / "The used list names something not in the model" / "Block {block}: the entry must hold {released} to give it back" / "Block {name}: the resources it holds are not valid" / "Block {where}: {name} is held but never released later" / "Block {block}: batch member {index} must hold {resource}" initial_state, resources
E_INITIAL_SCHEDULE_OFFSET error initial_state.schedule_offset is not a number >= 0. On screen: "Initial state: schedule offset must be 0 or more" initial_state, schedules
E_INITIAL_SET error initial_state names a resource set, a cursor or a member the model does not have. On screen: "Resource set {name}: its cursor is not valid" / "Block {block}: {member} is not a member of the set" initial_state, resource_sets
E_INITIAL_VARIABLE error initial_state.variables names a variable the model does not declare. On screen: "Initial state: unknown variable {name}" initial_state, variables
E_LEVEL_INITIAL_CYCLE error Level initial expressions read each other in a cycle. On screen: "Level start values depend on each other: {cycle}" initial_state, levels
E_MESMAP_FEED error An unknown feed, or a feed the model cannot take (no Orders-mode CREATE, no such process-time table, an override path that does not apply). On screen: "The MES mapping's feeds are not valid" / "Unknown MES feed {name}" / "The plan feed needs a model that takes orders" / "Table {name} is not in the model" / "An MES value could not be applied" CREATE
E_MESMAP_FORMAT error A *.mesmap.json is not an object, or needs a newer format version. On screen: "The MES mapping file is not valid" / "The MES mapping is from a newer version" --
E_MESMAP_PRODUCT error A product entry is malformed or duplicated, or names an entity type or sequence the model does not declare. On screen: "A product has no MES name" / "Product {name} is mapped twice" / "Product {name}: item type {type} not in the model" / "Product {name}: route {route} not in the model" --
E_MESMAP_TIME error A mapping has no time epoch, or an unknown model time unit. On screen: "The MES mapping does not say when its time starts" --
E_MESMAP_UNMAPPED error The MES reports a work centre, product or operation the mapping covers with nothing. On screen: "MES work centre {name} is not mapped" / "MES product {name} is not mapped" / "Step {step} of {name} has no work centre" / "Work waiting at {name} has no station" --
E_MESMAP_WORK_CENTRE error A work centre entry is malformed or duplicated, or names a station, resource or failure the model does not declare. On screen: "A work centre has no MES name" / "Work centre {name} is mapped twice" / "Work centre {name}: no station {station} in the model" / "Work centre {name}: its process time points nowhere usable" / "Work centre {name}: its process time is not in the model" / "Work centre {name}: {target} is not in the model" --
E_MES_ADAPTER error An adapter spec is not one this build knows (sqlite:<path> / csv:<folder>). On screen: "The MES connection type is not known" --
E_MES_READ error An MES source could not be read: missing file, missing table, bad columns. On screen: "The MES data cannot be read" --
E_MES_TIME error A timestamp is not ISO 8601. On screen: "A time from the MES cannot be read" --
E_OUTBOX_SINK error The outbox given at start is no sink this version builds, or its path is not a place a record may be written. On screen: "The outbox cannot be written there" --
E_PLANTMAP_DOUBLE error Two signals of a plant mapping tell one thing (a resource's units, a block's content): the engine does not choose between two reports. On screen: "Two plant signals report the same thing" --
E_PLANTMAP_FORMAT error The file is not a plant mapping of format 1, or a part of it is malformed. On screen: "The plant mapping file cannot be read" / "A plant mapping setting is not valid" / "Plant signal {index} is not valid" --
E_PLANTMAP_NAME error A plant mapping names a block, resource or level the model does not have. On screen: "Plant signal {index}: the model has no {what} {name}" / "Plant signal {index}: fleet {name} has no vehicle {unit}" / "Plant signal {index}: block {name} has no steps" --
E_PLANTMAP_SIZE error A plant mapping is over a bound (1 MiB, 2000 signals, 10 000 entries a table, 1024 bytes a key). On screen: "The plant mapping file is too large" / "The plant mapping has too many signals" / "Plant signal {index} is too large" --
E_PLANT_LOG error A recorded plant log cannot be read, or is over its bound (256 MiB, 1 000 000 lines). On screen: "The plant log cannot be read" --
E_RECOMMEND_KPI error The KPI the candidates are compared on is not in the forecast's table. On screen: "No KPI {kpi} in the forecast; nothing compared" --
E_REFIT error A refit file is not one of format 1, is over its bound, holds a key it may not, or names a factor that addresses no number of the model. --
E_RESOURCE_POWER_STATE error A resource's "power" names a state that is not busy/idle/blocked/down/off_shift. On screen: "Resource {name}: unknown power state {state}" resources
E_SDIMPORT_MDL error A Vensim .mdl file was refused before parsing: not decodable text, over the 20 MB cap, or a malformed equation section. --
E_SDIMPORT_UNSUPPORTED error An XMILE or Vensim construct sdimport/mdlimport does not translate (a module, a macro, a conveyor/queue stock, a XMILE dimension mapping, a Vensim '<->' equivalence, an unknown function or name, a GET XLS/DIRECT/DATA external reference, a variable name with a space); the owning variable is left out of the imported layout. --
E_SDIMPORT_XML error An XMILE file was refused before parsing: a DOCTYPE/ENTITY declaration, over the 20 MB cap, or not well-formed XML. --
E_SERIES_TIMES error A time series' sample times do not strictly increase. On screen: "Time series {name}: timestamps must increase" / "Time series {name}: times must increase" / "Time series {name}: step must be positive" timeseries_inputs
E_STATE_FORMAT error The file is not a state document of format 1, or holds a value that is not plain data. On screen: "The state file cannot be read" --
E_STATE_HASH error A state document does not match its own hash: it was edited after it was written. On screen: "The state file was changed after it was written" --
E_STATE_MODEL error A state document was taken for another model, or another version of this one. On screen: "The state file is for another model" --
E_STATE_SIZE error A state document is over the size bound (16 MiB, 100 000 entities). On screen: "The state file is too large" --
E_STATE_STALE error An observed state is older than the age the caller allows, or has no time stamp. On screen: "The plant state is too old to use" --
E_STATE_UNSUPPORTED error The run holds something a state cannot carry (the message names the kind); no partial state is written. On screen: "Cannot start: an item waits at {name}, amount unknown" / "This model cannot start from plant data yet" --
E_TIMESERIES_COUNTS error simulation.timeseries_counts is not a list of at most 1000 different block names, or names a block the model does not have. On screen: "Counted blocks must be a list of different names" / "Counted block {name} is not in the model" --
E_TWIN_FORECAST error A twin's forecast failed; the last good one is kept and the next is tried at its own time. On screen: "The forecast failed; the last one is kept" / "The forecast could not be read" --
E_TWIN_OUTPUT error A twin's result file could not be written; the next cycle writes again. On screen: "{name} could not be written" --
E_TWIN_REFIT error An adopted refit does not apply to the model started from the plant: no forecast is made with it. On screen: "The adopted refit does not fit the model; no forecast" --
E_TWIN_RESULT error No twin result of format 1 can be read from that directory. --
E_TWIN_STATE error This model cannot be started from the plant's state yet (the message names the kind): the twin goes on monitoring and makes no forecast. On screen: "No start could be made from the plant's state" / "This model cannot start from plant data yet" / "Cannot start from plant data: vehicles not mapped" --
E_VARIABLE_INITIAL error A variable's initial value is not a number, string or boolean. On screen: "Variable {name}: start value must be a number, text or true/false" initial_state, variables
E_VIEWER_MODEL error A model cannot be shared as a browser viewer as it is: it holds agent Python, a LOGIC block, something a plugin registered, a data source that was not frozen into the copy, or it is too large. LOGIC
W_DATA_ALLOW_NETWORK_IGNORED warning A data source carries "allow_network"; consent never comes from the model file and the key is stripped on load. On screen: "Data source {name}: {key} in the model file is ignored" network
W_INITIAL_STATE_WARMUP warning Both an initial state and a warm-up are set; warm-up discards the very history the initial state supplies. On screen: "Warm-up discards the initial state" initial_state
W_LAW warning A law check of the last run did not pass (nagasim.laws): a warning, never an error; it clears when the model changes. On screen: "Run check not met: {name}" --
W_LIVE_DROPPED warning A live source sent something over a bound or of a type that is not data; it was dropped and counted. On screen: "{source}: some data dropped" --
W_LIVE_GAP warning A live source's stream broke: an unknown number of events is missing. On screen: "{source}: stream broke; some events missing" --
W_LIVE_LIMIT warning A live source's server did not accept the message limit, so the size of what it sends is not bounded. On screen: "{source}: its server does not limit message size" --
W_LIVE_LOST warning A live source's buffer overflowed: events were dropped before they were read. On screen: "{source}: {lost} events dropped unread" --
W_LIVE_SKEW warning A live source's clock and this machine's differ by more than 30 seconds. On screen: "{source}: its clock is {skew} s off" --
W_MESMAP_UNUSED warning A mapped work centre or product the MES does not report. On screen: "{name} is mapped but not in the MES" --
W_MES_NAIVE_TIME warning An MES timestamp carries no UTC offset and was read as UTC. On screen: "Times without a time zone read as UTC" --
W_MES_TABLE_MISSING warning A REST MES source answered 404 for a table, which was read as empty. On screen: "MES table {table} not found; read as empty" tables
W_MES_THIN_DATA warning Too few observations in the window to refit a parameter; the model's own value stands. On screen: "Too few {what} in {days}; using the model's own {own}" / "Too few {what} in {days}; using the model's {kept}" / "No pattern in {n} {what}; using the model's own {own}" --
W_OUTBOX warning The outbox could not take a record, stopped at a ceiling, or took one again after a refusal. Said once a change; records wait until they expire. On screen: "The outbox takes records again" / "The outbox refused a record; trying again" / "The outbox file is full; nothing more written" / "Today's outbox limit reached; the rest waits for tomorrow" / "The replies cannot be read; trying again" --
W_PLANT_CONTRADICTION warning The plant said two things that do not agree; the stated rule was applied. On screen: "Level {level} and buffer {buffer} disagree; the parts count" / "Jobs reported for {n} unreleased or unknown orders" / "{n} released orders show fewer jobs than ordered" --
W_PLANT_DROPPED warning Plant observations were dropped: a value the mapping cannot read, a time out of range, a stale event, or something over a bound. Counted by reason. On screen: "{n} lines of the plant log skipped" --
W_PLANT_GAP warning The plant's log has a hole (events lost, or the stream broke): what was missed is not in the observed timeline. On screen: "Gaps in the plant log: {holes}; events missing: {lost}" --
W_PLANT_SERVICE_INFERRED warning A plant reports units of a resource busy and names no job: the longest-waiting entities of the one block that seizes it are taken as in service. On screen: "{busy} of {name} busy, {named} jobs named; the rest guessed" --
W_PLANT_SYNTHETIC warning The observed timeline holds events for items or units the plant did not name (a queue length, a unit count). On screen: "Events added for items the plant did not name" --
W_PLANT_TIME warning Plant observations had no source stamp, one ahead of its receipt, or came late; each was given a time by the stated rule. On screen: "Some plant event times were corrected" --
W_SDIMPORT_APPROX warning sdimport/mdlimport translated a construct with a documented approximation (a bare DELAY, a non-euler/rk4 method, a non-day/hour/minute/second time unit, a clock not starting at 0, a graphical function/lookup with no input equation). DELAY
W_STATE_NOT_COVERED warning An observed state says nothing about an element kind the model has; it starts as the model declares it. On screen: "{name} is down; it starts up" / "{name} starts its cycle afresh" / "Nothing read about {name}; the model's start is used" / "{n} orders have no release time; released now" / "Fleet {name} cannot be placed" / "A part at the end of belt {name} is not placed" --
W_TWIN_ALERT warning The alert sums found in a twin's directory were of another model, kept under other --alert-k / --alert-h limits, or could not be read: they start again from now (said once). On screen: "Alerts started again: the saved sums were for another model" / "Alerts started again: the saved sums used other limits" / "Alerts started again: the saved sums are unreadable" --
W_TWIN_CLOCK warning This machine's clock jumped against its own count of time between two cycles. On screen: "This computer's clock jumped {by} s" --
W_TWIN_CUT warning A twin's result was over a bound: the part named was left out (or, for a source with more events waiting than one cycle reads, read at the next cycle). On screen: "{source} is ahead; the rest is read next step" / "Too many KPIs; some are not in the result" / "{n} more problems not shown" / "Result too large; {key} left out" --
W_TWIN_FORECAST_BUSY warning A forecast was due while the previous one was still running: none was started. On screen: "Previous forecast still running; none started" --
W_TWIN_MODEL_CHANGED warning The model file changed on disk while a twin runs on it: the twin keeps the model it loaded until it is started again. On screen: "The model file changed; the twin keeps the loaded one" --
W_TWIN_RECOMMEND warning A twin's recommendations could not be kept or continued as asked: the message says what (a ledger of another model, a state too large to keep, an action that no longer applies). Said once. On screen: "The record of taken actions started again" / "A recommendation could not be kept; none delivered" / "An action taken on {target} no longer applies" / "The candidate actions could not be compared" / "The recommendations could not be updated" / "The recommendations could not be made" --
W_TWIN_REFIT warning A twin's refit could not be stepped or proposed, or an adopted refit kept in its directory is not applied (unsound, not the one the outbox ledger holds as taken, or outside the --refit file): the message says which. On screen: "The adopted refit is not applied" / "A kept refit is not applied: no refit file given" / "The refit could not be updated this cycle" / "A refit proposal was unreadable; not proposed" / "A refit taken by reply is not applied" --
W_TWIN_SCORE warning The rolling score found in a twin's directory was of another model or horizon, or could not be read: it starts again from now (said once). On screen: "Score started again: the saved one was for another model" / "Score started again: the saved one was for another horizon" / "Score started again: the saved one is unreadable" --
W_TWIN_SOURCE warning A source of the twin is down, has not answered yet, could not be read, has been silent for longer than --max-age, or says nothing the mapping reads: the view keeps its last picture and no forecast is started. On screen: "{source} is not answering" / "{source} silent for {age} s" / "Plant data matches no signal" / "The plant could not be read; trying again" --
W_VIEWER_EMPTY warning The model's dashboard definition lists no input or no result, so a viewer of it has nothing to change or nothing to show. --
W_VIEWER_LONG_RUN warning A run at the most replications a viewer allows is estimated to take over five minutes in a browser. --

How to fix

Each code with the usual remedy:

  • E_CANDIDATES: Write the candidates file as {"format": 1, "kind": ...} with only kpi, better, expires and candidates, each action exactly verb, target and value. Point every target at a block, resource or order the model declares; the message names the action refused.
  • E_CANDIDATE_VERB: Set the action's verb to a built verb: set_capacity, resequence, expedite, hold, release, reroute or setpoint. The hint lists the verbs this version builds.
  • E_CONN_FORMAT: Fix the connections file passed as --connections: write it as {"format": 1, "connections": {...}}, and correct the entry the message names. Paths in it resolve beside the file and must exist.
  • E_DATA_BINDING_NAME: Give every entry in data_bindings a non-empty name, and rename one of two bindings that share a name.
  • E_DATA_BINDING_SOURCE: Set the binding's source to the name of a data source declared under data_sources, or declare that source. The hint lists the declared ones.
  • E_DATA_BINDING_TARGET: Point the binding's target at a path the model has, for example resources.Nurse.capacity. Declare the resource first if it does not exist.
  • E_DATA_BINDING_TRANSFORM: Use a transform from the hint in the binding's transform, with the argument its form needs, such as quantile:0.9, table:KEY or series:TIME. For orders, write map as an object of column names.
  • E_DATA_CONNECTION: Set the live source's connection to the name of a connection of its kind in the caller's connections file (--connections). The person who runs the model defines it there, never in the model.
  • E_DATA_CREDENTIALS: Remove the password from the source's location. Write the whole URL as ${NAGASIM_DATA_DB_URL} and set that environment variable before the run.
  • E_DATA_EMPTY: Check the binding's filter and column: after filtering, the column must hold usable values (numbers, two distinct timestamps for a rate, an id column and a row per table key).
  • E_DATA_ENV: Set the environment variable the message names before the run, or edit the source's location so it no longer refers to it.
  • E_DATA_ENV_NAME: Rename the ${...} reference in the source to a variable whose name starts with NAGASIM_DATA_, such as ${NAGASIM_DATA_DB_URL}, and set that variable before the run.
  • E_DATA_FILTER: Write the binding's filter as an object of "column": value or "column op": value entries, with an operator from the hint and a column the source has.
  • E_DATA_NETWORK_REFUSED: Pass --allow-network to the naga command that runs the model if a network source is intended. Otherwise point the source at a local path or a mapped drive.
  • E_DATA_PATH_OUTSIDE_ROOT: Move the data file under the root the run is confined to, and set the source's location to a plain path under it; UNC, device and alternate-stream paths are refused.
  • E_DATA_PLAINTEXT_CREDENTIAL: Use the encrypted scheme for the connection in the connections file (https, mqtts, an OPC UA security policy), or drop its credential and read anonymously.
  • E_DATA_PROXY: Use the https URL for the source, or list the host in NO_PROXY if it is reachable directly. If the tunnel failed, check HTTPS_PROXY.
  • E_DATA_QUERY: Write the source's query as one SELECT (or WITH) statement, with no comment before it and no second statement after a semicolon.
  • E_DATA_READ: Check that the file exists at the path relative to the model file, and that the sheet, column or query is right. A network source must be reachable and permitted by the caller.
  • E_DATA_SOURCE_KIND: Set the data source's kind to one the hint lists. For a live reading, name a source of a live kind declared in the model's data_sources.
  • E_DATA_SOURCE_LOCATION: Give the data source a location its kind can use: a path or URL for a file source, a query for sqlite and sql. For a live kind, give only the path, topic, node ids or registers inside its connection.
  • E_DATA_SOURCE_NAME: Give every entry in data_sources a non-empty name, and rename one of two sources that share a name.
  • E_DATA_SOURCE_OPTION: Remove the unknown key from the source's options, or give the option a value it can take. The hint lists the options of that kind and the values allowed.
  • E_DATA_TLS: Give the server a certificate valid for its host name and dates, or name the private CA as ca_file in the connections file. A certificate file it names must be a PEM or DER certificate.
  • E_DATA_TOO_LARGE: Point the source at a smaller extract, so the response stays under the byte and row caps, with flatter rows for a rest source.
  • E_DATA_TYPE: Pick a transform whose result matches the type the target field holds, or point the binding's target elsewhere. Text from a live source is never written into the model; bind a number or a boolean.
  • E_DATA_URL_HOST: Write the source's location as http(s)://host/path with a hostname that resolves. If --allow-host restricts the run, add the host to it.
  • E_DATA_URL_PARAMETER: Remove the query parameters the hint does not allow from the database URL. Settings outside that list belong to the database account or a service file, not to the model.
  • E_DATA_URL_PRIVATE: Point the source at a public host. For an intranet host, pass --allow-private-network, or add "private": true to the connection in the connections file; loopback-only or metadata addresses stay refused for URLs.
  • E_DATA_URL_REDIRECT: Point the source's location, or the connection's address, at the final URL, so the fetch is not redirected, and keep it on https.
  • E_DATA_URL_SCHEME: Use an http or https URL in the source's location. A local file belongs in a csv, xlsx or sqlite source, never in a database URL.
  • E_FLEET_POWER_STATE: Key the fleet's power only by busy, idle, blocked, down or off_shift, and remove or rename any other state.
  • E_INITIAL_AGE: Set the entry's age in initial_state.entities to a number of at least 0, in base time units.
  • E_INITIAL_ARRIVALS: Give each CREATE in initial_state.arrivals a count of at least 0 and, for an Interarrival CREATE, a next at or after the clock; tied arrivals need different rank values.
  • E_INITIAL_BATCH: Give an entry that meets a SEPARATE its members, from 1 to the group size of the BATCH or MATCH that forms it. Each member has its own e_type, age, attributes and holds.
  • E_INITIAL_BELT: Correct the belt part in initial_state.entities: one entity at an accumulating CONVEYOR, with a stage it has and until or entered on the right side of the clock. Take the state at another time if a part blocks an end stop.
  • E_INITIAL_BLOCK: Make each initial_state.entities entry an object whose block names a block of the model, with valid attributes, place, held_by and transfer. Inside a submodel, name the block instance/inner.
  • E_INITIAL_BLOCK_TYPE: Move the entry in initial_state.entities to a block that can hold entities, such as a PROCESS or BUFFER, instead of the block type the message names.
  • E_INITIAL_BUSY: Make initial_state.resources busy equal to the units the in-service entities hold on that resource, or correct in_service in the entities.
  • E_INITIAL_CARRIER: Take the state with the carrier before the carrier BATCH (at its door SEIZE), not while it waits at the BATCH.
  • E_INITIAL_CLOCK: Set initial_state.clock to a number of at least 0 that lies before the end of the run, in the model's base time unit.
  • E_INITIAL_COUNT: Set the entry's count in initial_state.entities to a whole number of at least 0.
  • E_INITIAL_CYCLE: Give a cycle only to one in-service entity at a MOTION block, with a stage it has. Set until at or after the clock and within that segment, and give the time of each segment.
  • E_INITIAL_FAILURE: Name only failures the resource declares in initial_state.resources.NAME.failures, and give each a next or a down_until time.
  • E_INITIAL_FLEET: Correct initial_state.fleets or the entity's trip so each fleet, vehicle, node, charger and stage it names exists in the model. The message names the one missing.
  • E_INITIAL_IN_SERVICE: Lower in_service to at most the entry's count and the resource's capacity, or raise the capacity. Only service blocks take in_service.
  • E_INITIAL_KEY: Remove the unknown key from initial_state, or run the state with the engine version that wrote it. The hint lists the keys this engine knows.
  • E_INITIAL_ORDERS: Name only orders declared in orders in initial_state.orders, with created and completed of at least 0 and completed_at before the clock. Each order_book entry needs held true or false.
  • E_INITIAL_QUEUE_CAPACITY: Lower the number of entities waiting at the block, or parts on the belt, to what its queue, BUFFER or belt holds, or raise its capacity.
  • E_INITIAL_REMAINING: Give remaining one number of at least 0 per in-service entity. Set ends, deadline and arrives at or after the clock, and since and held_since at or before it.
  • E_INITIAL_RESOURCE: Name only resources declared in resources in initial_state.resources, used and an entity's holds. A hold must be released by a later block, and a released resource must be held.
  • E_INITIAL_SCHEDULE_OFFSET: Set initial_state.schedule_offset to a number of at least 0, how far into its cycle the calendar is at time 0.
  • E_INITIAL_SET: Name only declared resource sets in initial_state.resource_sets, with a cursor from -1 to the last member's index, and give member a resource of the set the block seizes.
  • E_INITIAL_VARIABLE: Declare the variable in variables, or remove it from initial_state.variables. The hint lists the declared variables.
  • E_LEVEL_INITIAL_CYCLE: Give one of the levels in the cycle a number as its initial, so the initial expressions no longer read each other in a loop.
  • E_MESMAP_FEED: Use only known keys under feeds, and give the model what each enabled feed writes: a CREATE with arrival_mode Orders for plan, a declared parameters.process_time_table. Check the mapped table, failure and scrap_target names exist in the model.
  • E_MESMAP_FORMAT: Make the mapping file a valid JSON object. Set format_version to a version this reader supports, or write the mapping in the older format.
  • E_MESMAP_PRODUCT: Give each products entry a unique mes id, as the MES reports it. Point entity_type and sequence at names the model declares, or set feeds.sequences to true to build routings from the MES.
  • E_MESMAP_TIME: Set time.epoch to an ISO 8601 instant for model time 0, such as 2026-09-21T06:00:00Z. Set time.unit to seconds, minutes, hours or days.
  • E_MESMAP_UNMAPPED: Add a work_centres or products entry for each MES id named, and map each work centre holding WIP to a STATION block that leads to a PROCESS. Fix a routing step with no work centre in the MES extract.
  • E_MESMAP_WORK_CENTRE: Give each work_centres entry a unique mes id. Point station, resource and failure at a STATION block, resource and failure the model declares, and make process_time_target a model path ending in .distribution.
  • E_MES_ADAPTER: Write the adapter spec as sqlite:<path>, csv:<folder> or rest:<connection>, with a location after the colon.
  • E_MES_READ: Make the source readable: the database file or CSV folder must exist and follow the MES table schema, with a one-row snapshot table holding taken_at. For a rest: source, check the connection's address and credential.
  • E_MES_TIME: Write the MES timestamp in ISO 8601 with a UTC offset, such as 2026-09-21T06:00:00Z.
  • E_OUTBOX_SINK: Give --outbox as file:<path> in an existing local folder (not a UNC or device path, a link or a hard-linked file), or as mqtt:<connection> naming an mqtt connection with "use": "outbox" in the connections file.
  • E_PLANTMAP_DOUBLE: Keep one signal for each count, state, level or resource's units in the plant mapping's signals. Tell a block's content either by a queue signal or by identities, not both. The engine does not choose between two reports.
  • E_PLANTMAP_FORMAT: Fix the *.plantmap.json at the path given: it needs "format": 1, a time.epoch ISO 8601 instant, only known keys, and signals whose as, key and tables match their kind. naga plant init writes a valid scaffold.
  • E_PLANTMAP_NAME: Correct the name in the signal (block, blocks, resource, level, nodes, sequences or unit) to one the model has; the hint lists the model's names. Check that the mapping is used with the model it was written for.
  • E_PLANTMAP_SIZE: Shrink the plant mapping under its bounds. The file stays under 1 MiB, with at most 2000 signals, at most 10 000 entries in each table, and each key at most 1024 bytes.
  • E_PLANT_LOG: Pass a readable log under 256 MiB and 1 000 000 lines, one JSON object a line, as naga watch --record writes it. Cut a longer log or record a shorter period.
  • E_RECOMMEND_KPI: Set kpi in the candidates file to a KPI of the forecast's table. Counted throughput is timeseries/block/<name>/out/max of a block the plant mapping counts.
  • E_REFIT: Fix the --refit file: "format": 1, "kind": "naga-refit", only its own keys, and a non-empty factors list, each {"path", "low", "high"} with low under high and a path that addresses a number of the model.
  • E_RESOURCE_POWER_STATE: Use only busy, idle, blocked, down and off_shift as keys of the resource's power object, each with a number of kW per unit; rename or remove any other key.
  • E_SDIMPORT_MDL: Re-save the Vensim .mdl file as plain text (UTF-8 or cp1252) under the 20 MB cap, and check that the path given to naga sdimport exists and is readable.
  • E_SDIMPORT_UNSUPPORTED: Rebuild the variable that the import left out, using the model file's own sections. The message names the unsupported construct, such as a module, a macro or an external data reference.
  • E_SDIMPORT_XML: Re-save the XMILE file as UTF-8, well-formed XML under the 20 MB cap, with no DOCTYPE or ENTITY declaration. Check that the path given to naga sdimport exists and is readable.
  • E_SERIES_TIMES: Sort the samples of the time series so times or timestamps strictly increase with no duplicates, and give step a positive value.
  • E_STATE_FORMAT: Pass a state document of format 1 as naga state take writes it, with finite numbers and plain JSON values only. Take the state again rather than writing one by hand.
  • E_STATE_HASH: Take the state again with naga state take instead of editing the file; a state document is checked against its own hash, so any hand edit refuses it.
  • E_STATE_MODEL: Take the state again with naga state take on the exact model file you run. A change to the model, or an engine upgrade that moves its hash, refuses an older state.
  • E_STATE_SIZE: Take the state at a time with fewer entities in the system, or reduce the model's work in progress; a state holds at most 16 MiB and 100 000 entities.
  • E_STATE_STALE: Write the observed state again so it carries a current time stamp, or allow an older state with a larger --max-age.
  • E_STATE_UNSUPPORTED: Take the state at another time, when the kind the message names is not in progress, or remove that element from the model. The coverage table of the state documentation lists what a state carries.
  • E_TIMESERIES_COUNTS: Set simulation.timeseries_counts to a list of at most 1000 different block names that exist in the model, for example ["Drill", "Pack"].
  • E_TWIN_FORECAST: Run the model from the same state with naga run --state to see why it fails, then fix the model; the twin keeps the last good forecast meanwhile.
  • E_TWIN_OUTPUT: Check the twin's --out directory: its write rights, its free space, and that no reader keeps twin.json or the ledger open. The next cycle writes again.
  • E_TWIN_REFIT: End the adopted refit with an ended reply in the outbox replies, or start the twin with the model the refit was adopted for.
  • E_TWIN_RESULT: Pass the --out directory of a twin that has written at least one cycle, a local folder holding its twin.json; start one with naga twin run ... --out DIR.
  • E_TWIN_STATE: Remove or replace the element kind the message names, or map a vehicle signal for every vehicle of each fleet. naga state check and the state coverage table show what can start from the plant.
  • E_VARIABLE_INITIAL: Give the variable's initial a scalar value: a number, a string or true/false, not a list or an object.
  • E_VIEWER_MODEL: Remove what the message names: freeze data_sources and data_bindings with naga viewer --freeze, drop agent python, LOGIC blocks and plugin types, or keep the model under 5 MB. Otherwise share a naga run --player recording.
  • W_DATA_ALLOW_NETWORK_IGNORED: Remove allow_network from the data source in the model file. Network access is granted by whoever runs the model (--allow-network), never by the file.
  • W_INITIAL_STATE_WARMUP: Set simulation.warmup to 0 for a model that starts from an initial_state, or remove the initial state if a warm-up from empty is what you want.
  • W_LAW: Compare the result the law names with the model's arrival rates, service times and capacities, and correct the input that disagrees. Saturation can be intended; with no warm-up or many entities left inside, add a warm-up or lengthen the run.
  • W_LIVE_DROPPED: Check what the source sends: keys and values must be plain data under the size bound. Its distinct keys must stay under the connection's keys limit, which limits in the connections file can raise.
  • W_LIVE_GAP: Check the connection to the source and the network or server behind it; the latest values are right again, but the history has a hole of unknown size.
  • W_LIVE_LIMIT: Use an encrypted OPC UA connection to a server you trust, lower the server's own message limits, or install an asyncua version the reader supports.
  • W_LIVE_LOST: Read the source more often, or raise the connection's events limit under limits in the connections file (ceiling 100 000).
  • W_LIVE_SKEW: Synchronise the clocks of the source and this machine, for example with NTP; both stamps travel with every event.
  • W_MESMAP_UNUSED: Correct the entry's mes id to the one the MES reports for that equipment, or remove the work_centres entry.
  • W_MES_NAIVE_TIME: Export the MES timestamps, in the events table and the snapshot table's taken_at, with a UTC offset such as Z. A source that writes local time otherwise shifts the history window by its offset.
  • W_MES_TABLE_MISSING: If the plant has the table, give the REST connection's credential access to it, or serve it at the connection's address. Otherwise no change is needed: the table reads as empty.
  • W_MES_THIN_DATA: Widen parameters.window_days or lower parameters.min_samples in the mapping. If no distribution could be fit, check the units and signs of the durations in the MES extract.
  • W_OUTBOX: Make the outbox reader open, read and close its file and the replies file, and move or empty a file at its ceiling. Failed records are retried until they expire; past the daily ceiling the rest is dropped until the next UTC day.
  • W_PLANT_CONTRADICTION: Check the plant signals the message counts by reason: a job for an unseen entity, a retyped entity, a level out of bounds, a counter going back. Fix the mapping, or set rollover on a counter that wraps.
  • W_PLANT_DROPPED: Check the mapping's tables (states, blocks, types) and fields against what the plant sends; the message counts each reason. A recorded log needs one JSON object a line, as naga watch --record writes.
  • W_PLANT_GAP: Check the plant connection and raise the source's events limit in the connections file if events were lost. What was missed is not shown; the next values put the timeline right.
  • W_PLANT_SERVICE_INFERRED: Map the station's job signal in the plant mapping, so the plant names which entities are in service instead of the longest-waiting ones being assumed.
  • W_PLANT_SYNTHETIC: Map identities with at, seen or job signals where the plant has them, so the timeline follows named items and units instead of counts alone.
  • W_PLANT_TIME: Synchronise the plant's clocks with this machine and have each signal carry a source stamp; the message counts stamps that were missing, ahead of their receipt or late.
  • W_SDIMPORT_APPROX: Check the translated element at the path given. To avoid it, set the source model's method to euler or rk4 and its time unit to day, hour, minute or second. Set its start time to 0, and give each graphical function an input.
  • W_STATE_NOT_COVERED: Map a plant signal for the element kind the message names, or take the state again with this version. If the model's declared start is acceptable for it, the warning can stay.
  • W_TWIN_ALERT: Use one --out directory per model and keep the same --alert-k and --alert-h when the twin is started again. If the change was intended, the sums restart and the warning can stay.
  • W_TWIN_CLOCK: Check this machine's time synchronisation. A single jump, such as a manual clock change, needs no action: cadences are not moved and later stamps use the new time.
  • W_TWIN_CUT: Reduce what one result holds: fewer KPIs or compared series in the forecast, or a smaller view. For a busy source, shorten --every so each cycle has fewer events to read.
  • W_TWIN_FORECAST_BUSY: Lengthen --forecast-every, or shorten --horizon or lower --replications, so each forecast ends before the next is due.
  • W_TWIN_MODEL_CHANGED: Stop the twin and start it again to use the changed model file; until then it keeps the model it loaded.
  • W_TWIN_RECOMMEND: Act on what the message names. Use one --out directory per model so its ledger matches, keep the start state under its size bound, and check that a taken action's target still exists in the model.
  • W_TWIN_REFIT: Give the twin the same --refit file it ran with, and adopt only refits whose factors that file allows; reply ended to a refit that should not apply.
  • W_TWIN_SCORE: Use one --out directory per model and --horizon. A twin started with another model or horizon restarts its score, and the warning can then stay.
  • W_TWIN_SOURCE: Check that each live source is up and connected, that --max-age is longer than its silent spells, and that the mapping's signal keys match what the plant sends (naga watch).
  • W_VIEWER_EMPTY: List at least one entry under dashboard.inputs and one under dashboard.results. If the author's run could not be recorded, run the model with naga run to see why.
  • W_VIEWER_LONG_RUN: Lower dashboard.limits.max_replications so a run at the most replications a viewer allows takes under five minutes in a browser.

All problem codes